ThorLabsPM101 - - TANGO Controls

This is historical information of device classes implemented in ThorLabsPM101 device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


Server for controlling the PM101 Power Meter from ThorLabs

Families: MeasureInstruments

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: ThorLabs

Product:

PM101

Bus: USB

Class interface


Attributes:

Name Description
AvgTimeScalar: DevDouble
AvgCntScalar: DevDouble
DarkAdjustStateScalar: DevDouble
DarkOffsetScalar: DevDouble
BeamDiaScalar: DevDouble
WavelengthScalar: DevDouble
CurrentAutoRangeScalar: DevLong
CurrentRangeScalar: DevDouble
PowerAutoRangeScalar: DevLong
PowerRangeScalar: DevDouble
VoltageAutoRangeScalar: DevLong
VoltageRangeScalar: DevDouble
AnalogOutputScalar: DevDouble
AnalogOutputSlopeScalar: DevDouble
PowerScalar: DevDouble
CurrentScalar: DevDouble
VoltageScalar: DevDouble
SensTemperatureScalar: DevDouble

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartDarkAdjustInput: DevVoid
Output: DevVoid
CancelDarkAdjustInput: DevVoid
Output: DevVoid

Pipes:

Properties:

18 Jun 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



21 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



14 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



7 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



31 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



3 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



19 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



12 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



29 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



15 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



8 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



1 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



3 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



2 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



19 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



12 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



21 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



14 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



7 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



31 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



3 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



19 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



12 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



29 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



15 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



8 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



1 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



2 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Apr 2020, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



4 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



21 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



14 Mar 2020, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:11 Apr 2020, 3:43 a.m.