This is historical information of device classes implemented in AMC100AttoCubeCtrl device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Contact:
Class Description
Class connecting to the hardware
Families: Motion
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: AttoCube
Product:
AMC100
Bus: Ethernet
Class interface
Attributes:
Commands:
| Name | Description |
|---|---|
| GetPositionInput: DevLong Axis number Output: DevLong Positioner position (nm) |
— |
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| SetOutputInput: DevVarLongArray Axis number, 0->disable 1 ->enable Output: DevVoid |
— |
| GetOutputInput: DevLong Axis number Output: DevLong Output status |
— |
| SetAmplitudeInput: DevVarLongArray Axis number, amplitude (mV) Output: DevVoid |
— |
| GetAmplitudeInput: DevLong Axis number Output: DevLong Amplitude (mV) |
— |
| SetFrequencyInput: DevVarLongArray Axis number, frequency (mHz) Output: DevVoid |
— |
| GetFrequencyInput: DevLong Axis number Output: DevLong Frequency (mHz) |
— |
| SetActorSelectionInput: DevVarLongStringArray Axis number, name Output: DevVoid |
Sets the name for the positioner on the selected axis |
| GetActorNameInput: DevLong Axis number Output: DevString Name of the selected axis |
— |
| SetAutoResetInput: DevVarLongArray Axis number, auto reset mode Output: DevVoid |
0: reset position every time the reference position is detected 1: do not reset the position every time the reference position is detected |
| GetAutoResetInput: DevLong Axis number Output: DevLong Auto reset status |
0: reset position every time the reference position is detected 1: do not reset the position every time the reference position is detected |
| GetStatusReferenceInput: DevLong Axis number Output: DevLong Status reference |
0: Reference position is valid 1: Reference position is invalid |
| SetMoveInput: DevVarLongArray Axis number, 0->disable 1 ->enable Output: DevVoid |
0: enable actor approach towards target position 1: disable actor approach towards target position |
| GetMoveInput: DevLong Axis number Output: DevLong Moving status |
Status of the approach of the actor to the target position 0 = not moving; 1 = moving |
| SetResetInput: DevLong Axis number Output: DevVoid |
Resets the actual position to zero and marks the reference position as invalid. |
| SetTargetPositionInput: DevVarLongArray Axis number, target position (nm) Output: DevVoid |
Sets the target position for the movement on the selected axis |
| SetTargetRangeInput: DevVarLongArray Axis number, target range (nm) Output: DevVoid |
Sets the target range around the target position in which the flag In Target Range become active |
| GetTargetRangeInput: DevLong Axis number Output: DevLong Target range (nm) |
Gets the range around the target position in which the flag In Target Range become active |
| GetStatusMovingInput: DevLong Axis number Output: DevLong Moving status |
Gets information about the status of the stage output 0: idle (no movement commands for positioner pending) 1: moving (positioner actively driven to target position) 2: pending (positioner in target range and not actively driven) |
| CloseInput: DevVoid Output: DevVoid |
Close the connection to the device |
Pipes:
Properties:
| Name | Description |
|---|---|
| IPAddressDevString | IP address of the controller |
Updated:
The device class has been updated.
You can see previous version here .
28 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
21 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
14 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
7 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
31 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
24 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
17 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
10 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
3 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
26 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
19 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
12 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
5 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
29 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
15 Aug 2020, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
8 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
1 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
25 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
18 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
11 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
4 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
27 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
13 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
6 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 May 2020, DS Admin
Created:
The device class has been added to catalogue.