This is historical information of device classes implemented in PiLCArrayBasedTG2 device server.
Use this link to find the valid information.
    
        
        
        
    
    Development status:
    New development
    
    Information status: Updated
    
        
    
    
    
    Contact:
    
        
    
Class Description
PiLC Trigger Generator based on customized arrays
Families: OtherInstruments
Key words:
Platform: Unix Like
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description | 
|---|---|
| FileToLoadScalar: DevString | Full path of the file with the arrays generating the triggers | 
| ArmScalar: DevLong | Set to 1 to start triggering and 0 to stop. | 
| CurrentEncoderValueScalar: DevLong | — | 
| CurrentCounterValueScalar: DevLong | — | 
| Signal1CounterValueScalar: DevLong | — | 
| Signal1NextPointScalar: DevDouble | — | 
| Signal2CounterValueScalar: DevLong | — | 
| Signal2NextPointScalar: DevDouble | — | 
| Signal3CounterValueScalar: DevLong | — | 
| Signal3NextPointScalar: DevDouble | — | 
| Signal4CounterValueScalar: DevLong | — | 
| Signal4NextPointScalar: DevDouble | — | 
| PositionConversionScalar: DevDouble | Conversion from enconder values to physical units: steps = conversion*units | 
| CurrentPositionScalar: DevDouble | — | 
| ModeScalar: DevLong | 0 -> timing mode, 1 -> encoder mode | 
| Signal5CounterValueScalar: DevLong | — | 
| Signal5NextPointScalar: DevDouble | — | 
| Signal6CounterValueScalar: DevLong | — | 
| Signal6NextPointScalar: DevDouble | — | 
| Signal1PulseWidthScalar: DevDouble | Time the signal stays in high level | 
| Signal2PulseWidthScalar: DevDouble | Time the signal stays in high level | 
| Signal3PulseWidthScalar: DevDouble | Time the signal stays in high level | 
| Signal4PulseWidthScalar: DevDouble | Time the signal stays in high level | 
| Signal5PulseWidthScalar: DevDouble | Time the signal stays in high level | 
| Signal6PulseWidthScalar: DevDouble | Time the signal stays in high level | 
| SignalTimeModeScalar: DevDouble | 0 -> once, 1 -> periodic repetition timing mode Bitwise for signal1, signal2, ... | 
| EncoderConfigScalar: DevLong | 0 -> encoder Quad AB 1 -> encoder step/direction | 
Commands:
| Name | Description | 
|---|---|
| StateInput: DevVoid Output: State Device state  | 
                        
                            This command gets the device state (stored in its device_state data member) and returns it to the caller. | 
| StatusInput: DevVoid Output: ConstDevString Device status  | 
                        
                            This command gets the device status (stored in its device_status data member) and returns it to the caller. | 
| LoadTriggerArraysInput: DevVoid Output: DevVoid  | 
                        
                            Loads the data readout from the FileToLoad file to the FPGA. | 
| CalibrateEncoderInput: DevDouble Position to load (in physical units) Output: DevVoid  | 
                        
                            Set encoder position to the given value (in physical units). | 
Pipes:
Properties:
| Name | Description | 
|---|---|
| PiLCDeviceDevString | Name of the PiLC tango device to connect to | 
Updated:
The device class has been updated.
You can see previous version here .
5 Dec 2020, DS Admin
Updated:
A device class has been added.
You can see previous version here .
5 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
19 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
13 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
6 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
9 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
2 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
25 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
18 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
11 Apr 2020, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
4 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
28 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
21 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
14 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
7 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
29 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
15 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
8 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
1 Feb 2020, DS Admin
Created:
The device class has been added to catalogue.