Class Description
Class for controlling the in-vacuum CCD camera model GE-VAC 2048 2048 BI from GreatEyes
Families: Acquisition
Key words:
Platform: Unix Like
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: GreatEyes
Product:
GE-VAC 2048 2048 BI
Bus: USB
Class interface
Attributes:
| Name | Description |
|---|---|
| ReadoutSpeedScalar: DevLong | Set readout speed. Read last set value. Sets pixel clock to [0..6] 0 -> 1 MHz 3 -> 3 MHz 5 -> 500 kHz 6 -> 50 kHz |
| ExposureTimeScalar: DevDouble | Set exposure time, read last set value. |
| BinningXScalar: DevLong | Number of pixels [1...numPixelInX] to be binned in x-direction (if supported by CCD). 0 -> no binning |
| BinningYScalar: DevLong | Number of pixels [1...numPixelInY] to be binned in y-direction. 0 -> no binning |
| GainScalar: DevLong | 0 -> Low ( Max. Dyn. Range ) 1 -> Std ( High Sensitivity ) |
| CapacityModeScalar: DevLong | 0 -> Standard ( Low Noise ) 1 -> Extended ( High Signal ) |
| CropModeXScalar: DevLong | Number of columns to readout |
| CropModeYScalar: DevLong | Number of lines to readout |
| CropModeScalar: DevLong | 1 -> active |
| CoolingTemperatureLevelScalar: DevLong | Adjust temperature of CCD sensoR |
| CoolingOffOnScalar: DevLong | Switch temperature control off/on (0/1) |
| SensorTemperatureScalar: DevLong | — |
| BacksideTemperatureScalar: DevLong | — |
| FileDirScalar: DevString | Path to the dector image files. |
| FilePrefixScalar: DevString | The prefix of the image files to be created. The full image file name will be composed as <br /> <b>prefix_number.postfix </b> <br /> when acquiring images. |
| FileStartNumScalar: DevLong | The file number used when saviing an image. |
| BiasCorrectionScalar: DevLong | 0 -> disable, 1->enable |
| SyncOutputScalar: DevLong | 1 -> Sets the “SYNC” TTL trigger output to TTL high level. 0 -> Sets the “SYNC” TTL trigger output to TTL low level. |
| OpenShutterScalar: DevLong | 0 -> close 1 -> open 2 -> auto shutter |
| ShutterOpenTimeScalar: DevDouble | Time to wait before the start of the exposure to ensure that the shutter is fully opened. |
| ShutterCloseTimeScalar: DevDouble | Time to wait after exposure and before starting the readout to ensure that the shutter is fully closed. |
| SyncOutputEnabledScalar: DevLong | 0 -> sync-output disabled 1 -> sync-output enabled |
| ShutterControlEnabledScalar: DevLong | 0 -> shutter control disabled 1 -> shutter control enabled |
| TriggerModeScalar: DevLong | 0 -> internally triggered |
| TriggerTimeoutScalar: DevFloat | Trigger timeout in seconds. Only used if trigger mode is 1 |
| LastSavedImageScalar: DevString | Complete path of the last saved image |
| SaveImageFilesScalar: DevLong | If 0 image files are not saved |
| ImageImage: DevUShort | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| StartAcqInput: DevVoid Output: DevVoid |
Start acquisition |
| StopAcqInput: DevVoid Output: DevVoid |
Stop acquisition |
| PrepareAcqInput: DevVoid Output: DevVoid |
Update settings. Automatically called if settings have been changed and StartAcq is called before preparing the acquisition. |
Pipes:
Properties:
Please log in to comment.
Updated:
The device class has been updated.
You can see previous version here .
8 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
1 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
25 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
18 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
11 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
4 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
27 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
13 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
6 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
9 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
2 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
25 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
18 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
11 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
4 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
28 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
21 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
14 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
7 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
29 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
15 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
8 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
1 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 May 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
9 Feb 2019, DS Admin
Created:
The device class has been added to catalogue.