This is historical information of device classes implemented in PhyMotionMotor device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
Class for controlling a channel in a phyMotion module
Families: Motion
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: Pythron
Product:
phyMotion
Bus: Socket
Class interface
Attributes:
| Name | Description |
|---|---|
| MovementTypeScalar: DevLong | Type of movement (free, relatib/absolute, reference move): 0 -> rotational 1 -> hardware limit switches 2 -> software limit switches 3 -> hw and sw limit switches |
| PositionUnitsScalar: DevLong | Position units: 1-> Step 2 -> mm 3 -> Zoll 4 -> Grad |
| BaseRateScalar: DevLong | The motor starts to move with this rate, then accelerates |
| SlewRateScalar: DevLong | The motor speed |
| AccelerationScalar: DevLong | The acceleration |
| UnitLimitMinScalar: DevDouble | — |
| UnitLimitMaxScalar: DevDouble | — |
| UnitBacklashScalar: DevDouble | — |
| PositionScalar: DevDouble | — |
| UnitCalibrationScalar: DevDouble | Position = (Hw position) + UnitCalibration |
| LimitSwitchTypeScalar: DevLong | 0 -> opener pos, neg, mit and ref limits 7 -> closer pos, neg, mit and ref limits |
| StopCurrentScalar: DevDouble | — |
| RunCurrentScalar: DevDouble | — |
| StepWidthScalar: DevLong | Step width: 0=1/1, 2=1/2, 3=1/4, 4=1/5, 5=1/8, 6=1/10, 7=1/16, 8=1/20, 9=1/32, 10=1/64, 11=1/128, 12=1/256, 13=1/512 |
| TemperatureScalar: DevDouble | Current temperature from power stage. |
| ConversionScalar: DevDouble | The conversion factor, steps = conversion*units |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| CalibrateInput: DevDouble Value to be calibrated Output: DevVoid |
Calibrate the motor: current position is calibrated to be the value given as an argument |
| StopMoveInput: DevVoid Output: DevVoid |
Stop Movement |
Pipes:
Properties:
| Name | Description |
|---|---|
| ModuleNbDevLong | Module Number |
| ChannelDevLong | Channel number |
| CtrlDeviceDevString | Name of the tango device making the socket connection |
Updated:
The device class has been updated.
You can see previous version here .
15 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
1 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
8 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Nov 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
18 Aug 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.