IK220 - - TANGO Controls

This is historical information of device classes implemented in IK220 device server.

Use this link to find the valid information.

Development status: Released
Information status: New

Contact:



Class Description


Class for encoder talking to IK220 PCI card of Heidenhain

Families: Instrumentation

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
PositionScalar: DevDouble Calculated position from encoder
OffsetScalar: DevDouble Offset for position calculation
ConversionScalar: DevDouble Conversion factor for position calculation
StatusPortScalar: DevLong —
P1Scalar: DevLong 0: Incremental encoder (default)\n1: EnDat encoder\n2: SSI encoder
P2Scalar: DevLong 0: 11 muApp (current measurement)\n1: 1 Vpp (voltage measurement) (default)
P3Scalar: DevLong 0: Linear axis\n1: Angular axis +/- infinite
P4Scalar: DevLong 0: Positive counting direction\n1: Negative counting direction
P5Scalar: DevLong 0 to 0xffffffff: Signal periods/revolution for angular\naxes, effective only if parameter 3 = 1, Default value 0
P6Scalar: DevLong 0: Single REF mark (default)\n500: distance-coded REF marks. Fixed interval 500 x GP\n1000: distance-coded REF marks. Fixed interval 1000 x GP\n2000: distance-coded REF marks. Fixed interval 2000 x GP\n5000: distance-coded REF marks. Fixed interval 5000 x GP
P7Scalar: DevLong 0 to 12: Number of interpolation bits (default 12)\nThe interpolation value (16-bit width, max 12 significant bits, \nleft-aligned) is rounded off to the number of set bits.
P8Scalar: DevLong 0: compensation for position value off (default).\n1: compensation for position value on
P9Scalar: DevLong 0: acquisition of compensation value off (default) \n1: acquisition of compensation value on
P10Scalar: DevLong 1 to 8: Number of measuring points per octant \nwithin a signal period for calculation of compensantion\nvalues. Default value 1.
P11Scalar: DevLong 16 to 47: Time interval for timer.\nDefault value 33 corresponds to 1 ms.
FlagIgnoreStatusScalar: DevLong If true: ignore status in reading position.

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
CalibrateInput: DevDouble
Calibrate position
Output: DevLong
Completion status
Calibrate encoder. Compute offset from calibrate and current positions.
InitEncoderInput: DevVoid
Output: DevLong
Completion status
Init encoder
SetCorrectionOffOnInput: DevLong
0 -> correction off, 1-> correction on (P9)
Output: DevLong
Completion status
Set correction off or on setting P9 to 0 or 1 respectively.
DoReferenceInput: DevVoid
Output: DevLong
Completion status
Start reference-seeking
CancelReferenceInput: DevVoid
Output: DevLong
Completion status
Cancel reference

Pipes:

Properties:

Name Description
ChannelDevUShort Channel number. 0 or 1, selecting /dev/enc/0 or /dev/enc/1.
ModeDevUShort 0 -> current measurement 1 -> voltage measurement
SimulationModeDevULong 0 real mode, 1 simulation mode
DeviceDirDevString Directory containing the encoder device files, e.g. /dev/ik220. Devices are expetected to be named DeviceDir/channelNumber, e.g. /dev/ik220/0, /dev/ik220/1 etc.

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:19 Jan 2017, 10:44 a.m.