Class Description
The SIS8800 is the MicroTCA equivalent to the SIS3820. This class supports the operation as a 16 channel scaler, all NIM/50 Ohm. It has 4 control inputs, 4k7 against 3.3 V. 0V is interpreted as logical 1, but will be inverted to comply with the SIS3820 behaviour.
Families: CounterTimer
Key words:
Platform: Unix Like
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: SIS
Bus: MicroTCA
Class interface
Attributes:
| Name | Description |
|---|---|
| CountsScalar: DevDouble | the counter contents of a channel, implicitly triggers a copy to the shadow register. It cannot be written. Use reset() to set it to 0. |
| OffsetScalar: DevDouble | the offset is subtrated from the counter reading |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| ResetInput: DevVoid Output: DevVoid return status |
Resets a channel, clears the coounter contents |
Pipes:
Properties:
| Name | Description |
|---|---|
| DeviceNameDevString | e.g. /dev/sis8800-s5 to select the device in the fifth slot of the MicroTCA crate. |
| SimulationModeDevULong | 0 real mode, 1 simulation mode |
| ChannelDevULong | channel number, 0 - 15 |
Updated:
The device class has been updated.
You can see previous version here .
27 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
13 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
6 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 Jul 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Jul 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Jul 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
9 Jul 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
2 Jul 2022, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
25 Jun 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
18 Jun 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
11 Jun 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
4 Jun 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
28 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
21 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
14 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
7 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
9 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
2 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
26 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
19 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
12 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
5 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
26 Feb 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
19 Feb 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
12 Feb 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
5 Feb 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
29 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
15 Jan 2022, DS Admin
Created:
The device class has been added to catalogue.