Class for controlling PS CCD Camera

Families: Acquisition

Key words:

Platform: Unix Like

Language: Python

License:

Contact:

Hardware


Manufacturer: Photonic Science

Product:

Gemstar Xray CCD

Bus: Socket

Class interface


Attributes:

Name Description
DeltaTimeScalar: DevLong
NumberOfImagesScalar: DevLong
XBinningScalar: DevLong
YBinningScalar: DevLong
SubAreaLeftScalar: DevLong
SubAreaRightScalar: DevLong
SubAreaTopScalar: DevLong
SubAreaBottomScalar: DevLong
ExposureTimeScalar: DevFloat
FileDirectoryScalar: DevString The capture image is saved at:\n'FileDirectory'\ 'FilePrefix'+'FileRefNumber'+'.'+'FileFormat'
FileSuffixScalar: DevString The captured image is saved at:\n'FileDirectory'\ 'FilePrefix'+'FileRefNumber'+'.'+'FileFormat'
FileRefNumberScalar: DevString The captured image is saved at:\n'FileDirectory'\ 'FilePrefix'+'FileRefNumber'+'.'+'FileFormat'
FileFormatScalar: DevString The captured image is saved at:\n'FileDirectory'\ 'FilePrefix'+'FileRefNumber'+'.'+'FileFormat'
FilePrefixScalar: DevString The captured image is saved at:\n'FileDirectory'\ 'FilePrefix'+'FileRefNumber'+'.'+'FileFormat'
ImageImage: DevLong

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
ResetInput: DevVoid
Output: DevVoid
OpenInput: DevVoid
Output: DevVoid
CloseInput: DevVoid
Output: DevVoid
SnapInput: DevVoid
Output: DevVoid
SaveInput: DevVoid
Output: DevVoid
AbortSnapInput: DevVoid
Output: DevVoid
SetCompressInput: DevLong
Output: DevVoid
Enable(1) or disable(0) the compression (using zlib) of the data returned in Image
SnapAndSave2Input: DevVoid
Output: DevVoid
Snap an image then, start a parallel thread to post-process and save the image using the path: 'FileDirectory'\ 'FilePrefix'+'FileRefNumber'+'.'+'FileFormat'
StartAcquisitionInput: DevVoid
Output: DevVoid
Performs Snap and Save NumberOfImages times, with DeltaTime ms between Snaps.

Pipes:

Properties:

Name Description
IPAdressDevString IP Adress
PortNbDevLong Port Number


Please log in to comment.

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:2 Jan 2017, 2:46 p.m.