Class Description


Class for controlling PS CCD Camera

Families: Acquisition

Key words:

Platform: Unix Like

Language: Python

License:

Contact:

Hardware


Manufacturer: Photonic Science

Product:

Gemstar Xray CCD

Bus: Socket

Class interface


Attributes:

Name Description
DeltaTimeScalar: DevLong —
NumberOfImagesScalar: DevLong —
XBinningScalar: DevLong —
YBinningScalar: DevLong —
SubAreaLeftScalar: DevLong —
SubAreaRightScalar: DevLong —
SubAreaTopScalar: DevLong —
SubAreaBottomScalar: DevLong —
ExposureTimeScalar: DevFloat —
FileDirectoryScalar: DevString The capture image is saved at:\n'FileDirectory'\ 'FilePrefix'+'FileRefNumber'+'.'+'FileFormat'
FileSuffixScalar: DevString The captured image is saved at:\n'FileDirectory'\ 'FilePrefix'+'FileRefNumber'+'.'+'FileFormat'
FileRefNumberScalar: DevString The captured image is saved at:\n'FileDirectory'\ 'FilePrefix'+'FileRefNumber'+'.'+'FileFormat'
FileFormatScalar: DevString The captured image is saved at:\n'FileDirectory'\ 'FilePrefix'+'FileRefNumber'+'.'+'FileFormat'
FilePrefixScalar: DevString The captured image is saved at:\n'FileDirectory'\ 'FilePrefix'+'FileRefNumber'+'.'+'FileFormat'
ImageImage: DevLong —

Commands:

Name Description
OpenInput: DevVoid
Output: DevVoid
—
CloseInput: DevVoid
Output: DevVoid
—
SnapInput: DevVoid
Output: DevVoid
—
SaveInput: DevVoid
Output: DevVoid
—
AbortSnapInput: DevVoid
Output: DevVoid
—
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
ResetInput: DevVoid
Output: DevVoid
—
SetCompressInput: DevLong
Output: DevVoid
Enable(1) or disable(0) the compression (using zlib) of the data returned in Image
SnapAndSave2Input: DevVoid
Output: DevVoid
Snap an image then, start a parallel thread to post-process and save the image using the path: 'FileDirectory'\ 'FilePrefix'+'FileRefNumber'+'.'+'FileFormat'
StartAcquisitionInput: DevVoid
Output: DevVoid
Performs Snap and Save NumberOfImages times, with DeltaTime ms between Snaps.

Pipes:

Properties:

Name Description
IPAdressDevString IP Adress
PortNbDevLong Port Number

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 9:16 a.m.