KepcoBOP - - TANGO Controls
.

Average: 0
Rating Count: 0

Development status: Released, Release: release_1_0_0
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/PowerSupply/KepcoBOP
Contact:



Class Description


Kepco Bipolar Operational Power supply device server

Families: PowerSupply

Key words:

Platform: All Platforms

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: Kepco

Product:

BOP

Bus: Serial Line

Class interface


Attributes:

Name Description
CurrentScalar: DevDouble —
CurrentSetpointScalar: DevDouble —
FlowControlScalar: DevBoolean —
ModeScalar: DevString —
RemoteScalar: DevBoolean —
VoltageScalar: DevDouble —
VoltageSetpointScalar: DevDouble —
OutputScalar: DevBoolean —

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
CMDInput: DevString
Output: DevString
Send the input parameter as received to the PS supply and return read back string from PS (if any)

Pipes:

Properties:

Name Description
SerialDeviceDevString The serial device to connect to. Two types are supported: 1) The name of the serial tango device to connect to. Serial and PySerial devices are supported 2) The name of the serial device to connect to (i.e. /dev/ttyS0). In this case the connection is direct and this server must be run on the machine where the serial port resides
MaxRetriesArray of DevLong Sometimes the instruments seems to get saturated and will not respond to some request: if you instrument is giving these kind of transient errors you can set how many retries you will allowe before going to FAULT state


Please log in to comment.

10 Nov 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:3 Jan 2017, 2:01 p.m.