.

Average: 0
Rating Count: 0

Development status: Released, Release: latest
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/OtherInstruments/MuxSwitcher
Contact:



Class Description


This device is a Device Multiplexer SWitcher . Switching the Mux is done through a Socket Server TCP/IP embeded in a RasperryPI3 board

Families: OtherInstruments

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: SOLEIL

Bus: TCP/UDP

Class interface


Attributes:

Name Description
muxNumScalar: DevUShort The Mux number .
muxNumHistorySpectrum: DevUShort History of values of the muxNum

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
ConnectInput: DevVoid
Output: DevVoid
Connect to Server TCP/IP
DisconnectInput: DevVoid
Output: DevVoid
Disconnect from Server TCP/IP
SendAnyCmdInput: DevString
Output: DevVoid
Send any command (string) to Server TCP/IP
ClearHistoryInput: DevVoid
Output: DevVoid
Clear MuxNumHistory attribute

Pipes:

Properties:

Name Description
ServerIPDevString The Address of the Server TCP/IP embeded on Rasperry board
ServerPortDevUShort The port of the Server TCP/IP embeded on Rasperry board
RcvEOLDevString Define the EOL of messages received from Server Tcp/Ip <CR> available values :<CR> CR<CR> LF<CR> FF<CR> HT<CR> VT<CR> SPACE<CR> NUL<CR>
SendEOLDevString Define the EOL of messages sent to Server Tcp/Ip <CR> available values :<CR> CR<CR> LF<CR> FF<CR> HT<CR> VT<CR> SPACE<CR> NUL<CR>
MuxNumMinDevUShort Define the minimum muxNum value
MuxNumMaxDevUShort Define the maximum muxNum value
AutoConnectDevBoolean Auto Connect at Init
RefreshAlwaysMuxNumDevBoolean Define if muxNum must be always refreshed from the Server IP.<CR> Otherwise, refresh is done only when user write at muxNum attribute.


Please log in to comment.

19 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



19 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



12 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Sep 2020, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:5 Sep 2020, 4:10 a.m.