PiLCScanTime - - TANGO Controls
.

Average: 0
Rating Count: 0

Development status: Released, Release: Release_1_0
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/OtherInstruments/PiLCScanTime
Contact:



Class Description


Class collecting extra data during a scan triggered by the PiLC with timing information

Families: OtherInstruments

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
NbTriggersScalar: DevLong Number of triggers. In automatic mode can not be written and will be read from the PiLCTriggerGenerator.
ManualModeScalar: DevLong If 1 nb of triggers can be set and the device has to be armed. If 0 it will follow the PiLCTriggerGenerator device.
FilePrefixScalar: DevString File to save the data
FileDirScalar: DevString Directory to save the data
ArmScalar: DevLong Set to 1 for start listening triggers and 0 to stop. Only active if not ManualMode.
RemainingTriggersScalar: DevLong Remaining triggers to read the data from
BufferLoadScalar: DevDouble Percentage of SDRAM buffer currently read
PiLCTGConnectedScalar: DevLong 0 -> not PiLCTriggerGenerator device connected
ExposureTimeScalar: DevDouble
TriggersPerFileScalar: DevLong Minimum number of trigger per file. If 0, all trigger will be written in the same file.
GateCounterScalar: DevLong
PiLCTimeScalar: DevLong
PiLCTimeOffsetScalar: DevLong
DeltaTriggerTimeScalar: DevDouble
ScanTimeScalar: DevDouble
CounterExScalar: DevLong
PiLCTimeStrScalar: DevString

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.

Pipes:

Properties:

Name Description
PiLCDeviceDevString Name of the PiLC tango device to connect to
PiLCTriggerGeneratorDeviceDevString Name of the PiLCTriggerGenerator device generating the triggers.


Please log in to comment.

29 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



15 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



8 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



1 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Jun 2020, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:20 Jun 2020, 4:11 a.m.