PiLCScanTime - - TANGO Controls

This is historical information of device classes implemented in PiLCScanTime device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


Class collecting extra data during a scan triggered by the PiLC with timing information

Families: OtherInstruments

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
NbTriggersScalar: DevLong Number of triggers. In automatic mode can not be written and will be read from the PiLCTriggerGenerator.
ManualModeScalar: DevLong If 1 nb of triggers can be set and the device has to be armed. If 0 it will follow the PiLCTriggerGenerator device.
FilePrefixScalar: DevString File to save the data
FileDirScalar: DevString Directory to save the data
ArmScalar: DevLong Set to 1 for start listening triggers and 0 to stop. Only active if not ManualMode.
RemainingTriggersScalar: DevLong Remaining triggers to read the data from
BufferLoadScalar: DevDouble Percentage of SDRAM buffer currently read
PiLCTGConnectedScalar: DevLong 0 -> not PiLCTriggerGenerator device connected
ExposureTimeScalar: DevDouble —
TriggersPerFileScalar: DevLong Minimum number of trigger per file. If 0, all trigger will be written in the same file.
GateCounterScalar: DevLong —
PiLCTimeScalar: DevLong —
PiLCTimeOffsetScalar: DevLong —
DeltaTriggerTimeScalar: DevDouble —
ScanTimeScalar: DevDouble —
CounterExScalar: DevLong —
PiLCTimeStrScalar: DevString —

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.

Pipes:

Properties:

Name Description
PiLCDeviceDevString Name of the PiLC tango device to connect to
PiLCTriggerGeneratorDeviceDevString Name of the PiLCTriggerGenerator device generating the triggers.

29 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Aug 2020, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



15 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



8 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



1 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Jun 2020, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:22 Aug 2020, 4:11 a.m.