This is historical information of device classes implemented in GotthardDetector device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Contact:
Class Description
Device for Gotthard detectors from PSI company.
Families: Acquisition
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: DECTRIS
Bus: Data Socket
Class interface
Attributes:
| Name | Description |
|---|---|
| nbChannelsScalar: DevLong | number of channels |
| nbFramesScalar: DevLong | Define the number of frames within an acquisition.<br> Available only with the Snap command.<br> With the Start command, it is always forced to 0, this is mean that we request an infinite number of frames. |
| currentFrameScalar: DevULong | Display the current frame number. Only relevant with the Snap command. |
| triggerModeScalar: DevString | Set/Get current trigger mode<br> <br> Available Trigger Modes are : INTERNAL_SINGLE<br> EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br> |
| exposureTimeScalar: DevDouble | Set/Get exposure time (in ms).<br> <br> Only relevant for these trigger modes :<br> INTERNAL_SINGLE<br> EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br> |
| latencyTimeScalar: DevDouble | Set/Get latency time (in ms).<br> <br> Only relevant for these trigger modes :<br> INTERNAL_SINGLE<br> EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br> |
| delayAfterTriggerScalar: DevDouble | set delay after trigger in ms for all modules. <br> Only relevant for these trigger modes :<br> EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br> |
| delayAfterTrigger1Scalar: DevDouble | get delay after trigger in ms of the first module. <br> Only relevant for these trigger modes :<br> EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br> |
| delayAfterTrigger2Scalar: DevDouble | get delay after trigger in ms of the second module. <br> Only relevant for these trigger modes :<br> EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br> |
| streamTypeScalar: DevString | Avalaible stream types:<br> NO_STREAM<br> LOG_STREAM <br> CSV_STREAM <br> NEXUS_STREAM<br> |
| streamTargetPathScalar: DevString | Defines the root path for generated Stream files. |
| streamTargetFileScalar: DevString | Define the file name for generated Stream files. |
| streamNbAcqPerFileScalar: DevULong | Define the number of acquisition for each Stream file. |
| fileGenerationScalar: DevBoolean | File generation after a snap command |
| estimatedFrameRateScalar: DevFloat | Estimated frame rate for the detector. |
| gainModeScalar: DevString | Set/Get gain mode.<br> <br> Available gain modes are :<br> DYNAMIC<br> LOW<br> MEDIUM<br> HIGH<br> VERY_HIGH<br> |
| enableDatasetframeScalar: DevBoolean | Allows to activate or inactivate the Frame saving in the nexus files.<br> |
| enableDatasetgainScalar: DevBoolean | Allows to activate or inactivate the gain saving in nexus files.<br> |
| acquisitionModeScalar: DevString | Avalaible acqusiition modes:<br> NORMAL<br> BURST<br> In BURST mode, the number of frames is limited to reach the highest frame rate. |
| acquisitionADCScalar: DevString | The detector can acquire data from all ADC or a single ADC.<br> Avalaible values:<br> ALL<br> 1<br> 2<br> 3<br> 4<br> 5<br> |
| frameSpectrum: DevLong | Last number of detected photons in each detector channel. |
| gainSpectrum: DevLong | Shows the gain value for each channel. |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
| SnapInput: DevVoid Output: DevVoid |
Arm/Start the acquisition. |
| StopInput: DevVoid Output: DevVoid |
Stop the acquisition. |
| GetDataStreamsInput: DevVoid Output: DevVarStringArray |
Returns the flyscan data streams associated with this device formatted as below :<br> |
| StreamResetIndexInput: DevVoid Output: DevVoid |
Reset the stream (Nexus) buffer index to 1. |
| SetCmdInput: DevString SlsDetector command Output: DevString SlsDetector response |
Allows to execute a line command (set type) |
| GetCmdInput: DevString SlsDetector command Output: DevString SlsDetector response |
Allows to execute a line command (get type) |
Pipes:
Properties:
| Name | Description |
|---|---|
| ConfigFileNameDevString | Configuration files used during the camera instanciation. |
| SpoolIDDevString | Used only by the FlyScan application |
| ExpertFramePacketNumberDevLong | Only an expert User could change this property.<br> This is the number of packet for each received frame part.<BR> |
| ExpertReadoutTimeAllADCDevDouble | Only an expert User could change this property.<br> This is the readout time in seconds of the camera.<BR> |
| ExpertReceiverFifoDepthDevLong | Only an expert User could change this property.<br> This is the number of frames in memory of the receiver.<BR> |
| ExpertStreamMemoryModeDevString | Only an expert User could change this property<br> Applicable for StreamNexus Only !<BR> Available Values :<BR> - COPY<BR> - NO_COPY<BR> |
| MemorizedStreamTargetPathDevString | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedStreamTargetFileDevString | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedStreamTypeDevString | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedStreamNbAcqPerFileDevULong | Only the device could modify this property <br> The User should never change this property<br> |
| ExpertStreamWriteModeDevString | Only an expert User could change this property<br> Applicable for StreamNexus Only !<BR> Available Values :<BR> - ASYNCHRONOUS<BR> - SYNCHRONOUS<BR> - DELAYED<BR> |
| MemorizedFileGenerationDevBoolean | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedTriggerModeDevString | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedNbFramesDevLong | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedExposureTimeDevDouble | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedLatencyTimeDevDouble | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedDelayAfterTriggerDevDouble | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedGainModeDevString | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedEnableDatasetgainDevBoolean | Only the device could modify this property <br> The User should never change this property<br> |
| ExpertReadoutTimeSingleADCDevDouble | Only an expert User could change this property.<br> This is the readout time in seconds of the camera using ADC Roi.<BR> |
| ExpertBurstModeMaxFramesDevLong | Only an expert User could change this property.<br> This is the maximum number of frames which can be set with a BURST acquisition mode.<BR> |
| MemorizedAcquisitionModeDevString | Only the device could modify this property <br> The User should never change this property<br> |
| MemorizedAcquisitionADCDevString | Only the device could modify this property <br> The User should never change this property<br> |
| ExpertDetectorTypeDevString | Only an expert User could change this property<br> Applicable for StreamNexus Only !<BR> Available Values :<BR> - GOTTHARD<BR> - SIMULATOR<BR> |
README
b'### Documentation\nDetailed documentation can be found on the official site.\n\n### Binaries\nDocumentation to obtain the binaries via the conda package is available here.\n\n### Source code\nOne can also obtain the source code from this repository and compile while realizing the setup dependencies as required.\n\ngit clone https://github.com/slsdetectorgroup/slsDetectorPackage.git --branch 3.1.0\n\n\n#### Setup dependencies \n Gui Client
\nRequirements: Qt 4.8 and Qwt 6.0\n\n export QTDIR=/usr/local/Trolltech/\n export QWTDIR=/usr/local/qwt-6.0.1/\n\nIf either of them does not exist, the GUI client will not be built.\n\n Calibration wizards
\nRequirements: ROOT\n\n export ROOTSYS=/usr/local/root-5.34\n\n\n#### Compilation \n\nCompiling can be done in two ways.\n\n1. Compile using script cmk.sh
\n\nAfter compiling, the libraries and executables will be found in slsDetectorPackage/build/bin directory
\n\nUsage: [-c] [-b] [-h] [-d HDF5 directory] [-j]
\n * -[no option]: only make
\n * -c: Clean
\n * -b: Builds/Rebuilds CMake files normal mode
\n * -h: Builds/Rebuilds Cmake files with HDF5 package
\n * -d: HDF5 Custom Directory
\n * -t: Build/Rebuilds only text client
\n * -r: Build/Rebuilds only receiver
\n * -g: Build/Rebuilds only gui
\n * -j: Number of threads to compile through
\n \nFor only make:\n./cmk.sh\n\nFor make clean;make:\n./cmk.sh -c\n\nFor using hdf5 without custom dir /blabla:\n./cmk.sh -h -d /blabla\n\nFor rebuilding cmake without hdf5 \n./cmk.sh -b\n\nFor using multiple cores to compile faster:\n./cmk.sh -j9
\n\n\nFor rebuilding only certain sections
\n./cmk.sh -tg #only text client and gui
\n./cmk.sh -r #only receiver
\n\n\n2. Compile without script
\nUse cmake to create out-of-source builds, by creating a build folder parallel to source directory.\n\n $ cd ..\n $ mkdir slsDetectorPackage-build\n $ cd slsDetectorPackage-build\n $ cmake ../slsDetectorPackage -DCMAKE_BUILD_TYPE=Debug -DUSE_HDF5=OFF \n $ make\n\n\nUse the following as an example to compile statically and using specific hdf5 folder\n\n $ HDF5_ROOT=/opt/hdf5v1.10.0 cmake ../slsDetectorPackage -DCMAKE_BUILD_TYPE=Debug -DUSE_HDF5=ON\n \nAfter compiling, the libraries and executables will be found at bin directory\n\n $ ls bin/\n gui_client libSlsDetector.a libSlsDetector.so libSlsReceiver.a libSlsReceiver.so\n sls_detector_acquire sls_detector_get slsDetectorGui sls_detector_help sls_detector_put slsReceiver\n\n'
Updated:
The device class has been updated.
You can see previous version here .
15 Sep 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
4 Aug 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
21 Jul 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
14 Jul 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
7 Jul 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 Jun 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Jun 2018, DS Admin
Created:
The device class has been added to catalogue.