This is historical information of device classes implemented in GotthardDetector device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


Device for Gotthard detectors from PSI company.

Families: Acquisition

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: DECTRIS

Bus: Data Socket

Class interface


Attributes:

Name Description
nbChannelsScalar: DevLong number of channels
nbFramesScalar: DevLong Define the number of frames within an acquisition.<br> Available only with the Snap command.<br> With the Start command, it is always forced to 0, this is mean that we request an infinite number of frames.
currentFrameScalar: DevULong Display the current frame number. Only relevant with the Snap command.
triggerModeScalar: DevString Set/Get current trigger mode<br> <br> Available Trigger Modes are : INTERNAL_SINGLE<br> EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br>
exposureTimeScalar: DevDouble Set/Get exposure time (in ms).<br> <br> Only relevant for these trigger modes :<br> INTERNAL_SINGLE<br> EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br>
latencyTimeScalar: DevDouble Set/Get latency time (in ms).<br> <br> Only relevant for these trigger modes :<br> INTERNAL_SINGLE<br> EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br>
delayAfterTriggerScalar: DevDouble set/get delay after trigger in ms. <br> Only relevant for these trigger modes :<br> EXTERNAL_SINGLE<br> EXTERNAL_MULTIPLE<br>
streamTypeScalar: DevString Avalaible stream types:<br> NO_STREAM<br> LOG_STREAM <br> CSV_STREAM <br> NEXUS_STREAM<br>
streamTargetPathScalar: DevString Defines the root path for generated Stream files.
streamTargetFileScalar: DevString Define the file name for generated Stream files.
streamNbAcqPerFileScalar: DevULong Define the number of acquisition for each Stream file.
fileGenerationScalar: DevBoolean File generation after a snap command
estimatedFrameRateScalar: DevFloat Estimated frame rate for the detector.
gainModeScalar: DevString Set/Get gain mode.<br> <br> Available gain modes are :<br> DYNAMIC<br> LOW<br> MEDIUM<br> HIGH<br> VERYHIGH<br>
enableDatasetframeScalar: DevBoolean Allows to activate or inactivate the Frame saving in the nexus files.<br>
enableDatasetgainScalar: DevBoolean Allows to activate or inactivate the gain saving in nexus files.<br>
acquisitionModeScalar: DevString Avalaible acqusiition modes:<br> NORMAL<br> BURST<br> In BURST mode, the number of frames is limited to reach the highest frame rate.
acquisitionADCScalar: DevString The detector can acquire data from all ADC or a single ADC.<br> Avalaible values:<br> ALL<br> 1<br> 2<br> 3<br> 4<br> 5<br>
frameSpectrum: DevLong Last number of detected photons in each detector channel.
gainSpectrum: DevLong Shows the gain value for each channel.

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
SnapInput: DevVoid
Output: DevVoid
Arm/Start the acquisition.
StopInput: DevVoid
Output: DevVoid
Stop the acquisition.
StartInput: DevVoid
Output: DevVoid
Start the acquisition.
GetDataStreamsInput: DevVoid
Output: DevVarStringArray
Returns the flyscan data streams associated with this device formatted as below :<br>
StreamResetIndexInput: DevVoid
Output: DevVoid
Reset the stream (Nexus) buffer index to 1.
SetCmdInput: DevString
SlsDetector command
Output: DevString
SlsDetector response
Allows to execute a line command (set type)
GetCmdInput: DevString
SlsDetector command
Output: DevString
SlsDetector response
Allows to execute a line command (get type)

Pipes:

Properties:

Name Description
ConfigFileNameDevString Configuration files used during the camera instanciation.
SpoolIDDevString Used only by the FlyScan application
ExpertFramePacketNumberDevLong Only an expert User could change this property.<br> This is the number of packet for each received frame part.<BR>
ExpertReadoutTimeAllADCDevDouble Only an expert User could change this property.<br> This is the readout time in seconds of the camera.<BR>
ExpertReceiverFifoDepthDevLong Only an expert User could change this property.<br> This is the number of frames in memory of the receiver.<BR>
ExpertStreamMemoryModeDevString Only an expert User could change this property<br> Applicable for StreamNexus Only !<BR> Available Values :<BR> - COPY<BR> - NO_COPY<BR>
MemorizedStreamTargetPathDevString Only the device could modify this property <br> The User should never change this property<br>
MemorizedStreamTargetFileDevString Only the device could modify this property <br> The User should never change this property<br>
MemorizedStreamTypeDevString Only the device could modify this property <br> The User should never change this property<br>
MemorizedStreamNbAcqPerFileDevULong Only the device could modify this property <br> The User should never change this property<br>
ExpertStreamWriteModeDevString Only an expert User could change this property<br> Applicable for StreamNexus Only !<BR> Available Values :<BR> - ASYNCHRONOUS<BR> - SYNCHRONOUS<BR> - DELAYED<BR>
MemorizedFileGenerationDevBoolean Only the device could modify this property <br> The User should never change this property<br>
MemorizedTriggerModeDevString Only the device could modify this property <br> The User should never change this property<br>
MemorizedNbFramesDevLong Only the device could modify this property <br> The User should never change this property<br>
MemorizedExposureTimeDevDouble Only the device could modify this property <br> The User should never change this property<br>
MemorizedLatencyTimeDevDouble Only the device could modify this property <br> The User should never change this property<br>
MemorizedDelayAfterTriggerDevDouble Only the device could modify this property <br> The User should never change this property<br>
MemorizedGainModeDevString Only the device could modify this property <br> The User should never change this property<br>
MemorizedEnableDatasetgainDevBoolean Only the device could modify this property <br> The User should never change this property<br>
ExpertReadoutTimeSingleADCDevDouble Only an expert User could change this property.<br> This is the readout time in seconds of the camera using ADC Roi.<BR>
ExpertBurstModeMaxFramesDevLong Only an expert User could change this property.<br> This is the maximum number of frames which can be set with a BURST acquisition mode.<BR>
MemorizedAcquisitionModeDevString Only the device could modify this property <br> The User should never change this property<br>
MemorizedAcquisitionADCDevString Only the device could modify this property <br> The User should never change this property<br>
ExpertDetectorTypeDevString Only an expert User could change this property<br> Applicable for StreamNexus Only !<BR> Available Values :<BR> - GOTTHARD<BR> - SIMULATOR<BR>

README

b'### Documentation\nDetailed documentation can be found on the official site.\n\n### Binaries\nDocumentation to obtain the binaries via the conda package is available here.\n\n### Source code\nOne can also obtain the source code from this repository and compile while realizing the setup dependencies as required.\n\ngit clone https://github.com/slsdetectorgroup/slsDetectorPackage.git --branch 3.1.0\n\n\n#### Setup dependencies \n Gui Client
\nRequirements: Qt 4.8 and Qwt 6.0\n\n export QTDIR=/usr/local/Trolltech/\n export QWTDIR=/usr/local/qwt-6.0.1/\n\nIf either of them does not exist, the GUI client will not be built.\n\n
Calibration wizards
\nRequirements: ROOT\n\n export ROOTSYS=/usr/local/root-5.34\n\n\n#### Compilation \n\nCompiling can be done in two ways.\n\n1. Compile using script cmk.sh
\n\nAfter compiling, the libraries and executables will be found in slsDetectorPackage/build/bin directory
\n\nUsage: [-c] [-b] [-h] [-d HDF5 directory] [-j]
\n * -[no option]: only make
\n * -c: Clean
\n * -b: Builds/Rebuilds CMake files normal mode
\n * -h: Builds/Rebuilds Cmake files with HDF5 package
\n * -d: HDF5 Custom Directory
\n * -t: Build/Rebuilds only text client
\n * -r: Build/Rebuilds only receiver
\n * -g: Build/Rebuilds only gui
\n * -j: Number of threads to compile through
\n \nFor only make:\n./cmk.sh\n\nFor make clean;make:\n./cmk.sh -c\n\nFor using hdf5 without custom dir /blabla:\n./cmk.sh -h -d /blabla\n\nFor rebuilding cmake without hdf5 \n./cmk.sh -b\n\nFor using multiple cores to compile faster:\n./cmk.sh -j9
\n\n\nFor rebuilding only certain sections
\n./cmk.sh -tg #only text client and gui
\n./cmk.sh -r #only receiver
\n\n\n2. Compile without script
\nUse cmake to create out-of-source builds, by creating a build folder parallel to source directory.\n\n $ cd ..\n $ mkdir slsDetectorPackage-build\n $ cd slsDetectorPackage-build\n $ cmake ../slsDetectorPackage -DCMAKE_BUILD_TYPE=Debug -DUSE_HDF5=OFF \n $ make\n\n\nUse the following as an example to compile statically and using specific hdf5 folder\n\n $ HDF5_ROOT=/opt/hdf5v1.10.0 cmake ../slsDetectorPackage -DCMAKE_BUILD_TYPE=Debug -DUSE_HDF5=ON\n \nAfter compiling, the libraries and executables will be found at bin directory\n\n $ ls bin/\n gui_client libSlsDetector.a libSlsDetector.so libSlsReceiver.a libSlsReceiver.so\n sls_detector_acquire sls_detector_get slsDetectorGui sls_detector_help sls_detector_put slsReceiver\n\n'

3 Nov 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



15 Sep 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Aug 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



21 Jul 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



14 Jul 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



7 Jul 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 Jun 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Jun 2018, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:21 Jul 2018, 3:02 a.m.