This is historical information of device classes implemented in Medipix device server.
Use this link to find the valid information.
Development status:
Released
Information status: Updated
Contact:
Class Description
Families: Acquisition
Key words: 2D
Platform: All Platforms
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Ethernet
Class interface
Attributes:
| Name | Description |
|---|---|
| DeviceIdScalar: DevLong | — |
| NumberOfChipsScalar: DevLong | — |
| NumberOfRowsScalar: DevLong | — |
| ExposureTimeScalar: DevDouble | — |
| NumberOfFramesScalar: DevLong | — |
| DirectoryScalar: DevString | — |
| FileNameScalar: DevString | — |
| ChipBoardIDScalar: DevString | — |
| InterfaceNameScalar: DevString | — |
| AcquisitionTypeScalar: DevUShort | — |
| AcquisitionTypesScalar: DevString | — |
| MaskBitFileAsciiScalar: DevString | — |
| TestBitFileAsciiScalar: DevString | — |
| LowTHSFileAsciiScalar: DevString | — |
| HighTHSFileAsciiScalar: DevString | — |
| WriteFilesScalar: DevBoolean | — |
| AcquisitionModeScalar: DevLong | — |
| PolarityScalar: DevBoolean | — |
| BiasVoltageScalar: DevDouble | — |
| SaveBinaryScalar: DevBoolean | — |
| AppendScalar: DevBoolean | — |
| FrameDataTypeScalar: DevLong | — |
| RepeatScalar: DevUShort | — |
| DelayScalar: DevDouble | — |
| MedipixTypeScalar: DevString | — |
| DACValuesAsStringScalar: DevString | — |
| FlipHorizontalScalar: DevBoolean | — |
| FlipVerticalScalar: DevBoolean | — |
| RotateScalar: DevDouble | — |
| DACNamesSpectrum: DevString | — |
| DACValuesSpectrum: DevUShort | — |
| DACValuesAnalogSpectrum: DevDouble | — |
| InterfaceSpecificInfosSpectrum: DevString | — |
| AcquisitionModesSpectrum: DevString | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| GetDACValueInput: DevString Output: DevUShort |
None. |
| LoadBinaryPixelsCfgInput: DevString Output: DevVoid |
None. |
| LoadHighThresholdsInput: DevString Output: DevVoid |
None. |
| LoadLowThresholdsInput: DevString Output: DevVoid |
None. |
| LoadMaskBitsInput: DevString Output: DevVoid |
None. |
| LoadTestBitsInput: DevString Output: DevVoid |
None. |
| PerformAcquisitionInput: DevVoid Output: DevVoid |
None. |
| PerformFrameAcquisitionInput: DevVoid Output: DevVoid |
None. |
| SetDACValueInput: DevString Output: DevDouble |
Sets a DAC value. The input argument must have the form . |
| StartTriggerInput: DevVoid Output: DevVoid |
None. |
| StopTriggerInput: DevVoid Output: DevVoid |
None. |
| PerformIntegralAcquisitionInput: DevVoid Output: DevVoid |
None. |
| ResetPixelConfigurationInput: DevVoid Output: DevVoid |
None. |
| SetDACsToDefaultInput: DevVoid Output: DevVoid |
None. |
| AbortInput: DevVoid Output: DevVoid |
None. |
| SaveConfigInput: DevVoid Output: DevVoid |
None. |
Pipes:
Properties:
| Name | Description |
|---|---|
| StorageDevString | Storage type (FILE_STORE, or TANGO_STORE)\nTANGO_STORE must be given like this `TANGO_STORE:some/tango/device` |
| ConfigDirectoryDevString | — |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:16 Feb 2018, 11:40 a.m.