Class Description


Families: Acquisition

Key words: 2D

Platform: All Platforms

Language: Cpp

License:

Contact:

Hardware


Manufacturer: none

Bus: Ethernet

Class interface


Attributes:

Name Description
DeviceIdScalar: DevLong —
NumberOfChipsScalar: DevLong —
NumberOfRowsScalar: DevLong —
ExposureTimeScalar: DevDouble —
NumberOfFramesScalar: DevLong —
DirectoryScalar: DevString —
FileNameScalar: DevString —
ChipBoardIDScalar: DevString —
InterfaceNameScalar: DevString —
AcquisitionTypeScalar: DevUShort —
AcquisitionTypesScalar: DevString —
MaskBitFileAsciiScalar: DevString —
TestBitFileAsciiScalar: DevString —
LowTHSFileAsciiScalar: DevString —
HighTHSFileAsciiScalar: DevString —
WriteFilesScalar: DevBoolean —
AcquisitionModeScalar: DevLong —
PolarityScalar: DevBoolean —
BiasVoltageScalar: DevDouble —
SaveBinaryScalar: DevBoolean —
AppendScalar: DevBoolean —
FrameDataTypeScalar: DevLong —
RepeatScalar: DevUShort —
DelayScalar: DevDouble —
MedipixTypeScalar: DevString —
DACValuesAsStringScalar: DevString —
FlipHorizontalScalar: DevBoolean —
FlipVerticalScalar: DevBoolean —
RotateScalar: DevDouble —
DACNamesSpectrum: DevString —
DACValuesSpectrum: DevUShort —
DACValuesAnalogSpectrum: DevDouble —
InterfaceSpecificInfosSpectrum: DevString —
AcquisitionModesSpectrum: DevString —

Commands:

Name Description
SetDACValueInput: DevString
Output: DevDouble
Sets a DAC value. The input argument must have the form .
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
GetDACValueInput: DevString
Output: DevUShort
None.
LoadBinaryPixelsCfgInput: DevString
Output: DevVoid
None.
LoadHighThresholdsInput: DevString
Output: DevVoid
None.
LoadLowThresholdsInput: DevString
Output: DevVoid
None.
LoadMaskBitsInput: DevString
Output: DevVoid
None.
LoadTestBitsInput: DevString
Output: DevVoid
None.
PerformAcquisitionInput: DevVoid
Output: DevVoid
None.
PerformFrameAcquisitionInput: DevVoid
Output: DevVoid
None.
StartTriggerInput: DevVoid
Output: DevVoid
None.
StopTriggerInput: DevVoid
Output: DevVoid
None.
PerformIntegralAcquisitionInput: DevVoid
Output: DevVoid
None.
ResetPixelConfigurationInput: DevVoid
Output: DevVoid
None.
SetDACsToDefaultInput: DevVoid
Output: DevVoid
None.
AbortInput: DevVoid
Output: DevVoid
None.
SaveConfigInput: DevVoid
Output: DevVoid
None.

Pipes:

Properties:

Name Description
StorageDevString Storage type (FILE_STORE, or TANGO_STORE)\nTANGO_STORE must be given like this `TANGO_STORE:some/tango/device`
ConfigDirectoryDevString —

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.