APDDetector - - TANGO Controls

This is historical information of device classes implemented in APDDetector device server.

Use this link to find the valid information.

Development status: Released, Release: Release_1_12
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/1D/APDDetector
Contact:



Class Description


Class for controlling the APD Detector Head from FMB Oxford.

Families: Instrumentation

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: FMB Oxford

Product:

APD ACE Electronics

Bus: Not Applicable

Class interface


Attributes:

Name Description
BiasSetpointScalar: DevDouble Bias setpoint of the head in v.
HeadStateScalar: DevString Head state.
SCAModeScalar: DevString Mode of the SCA: INT or WIN
SCALowThScalar: DevDouble Low level discriminator level.
SCAWinThScalar: DevDouble Window width (only used in WIN mode).
RateWinScalar: DevDouble Rate meter value in WIN mode.
RateIntScalar: DevDouble Rate meter value in INT mode.
HVStateScalar: DevString —
HeadTemperatureScalar: DevDouble Temperature of the head. Range of measurement from 0 to 50 C with a resolution of 0.05 C.
HeadCurrentScalar: DevDouble Current of bias voltage of the head. Range from 0 to 11 uA, with a resolution of 24nA.
CountingSourceScalar: DevString Selects/Returns the current counting source: SCA or TRG
CountsScalar: DevLong —
HeadVoltageScalar: DevDouble Bias voltage of the head. Range from 0 to 655 V, with a resolution of 0.6V
CounterStatusScalar: DevString —
ErrorInfoScalar: DevString —
VersionScalar: DevString Firmware version
SCAOutputScalar: DevLong Read/set the SCA output parameter. \nThis parameter is the time shaping of the SCA output in ns. \nPossible values: 5, 10, 20 or 30.
ScanLowLimitScalar: DevDouble Used as low limit for the scan,
ScanHighLimitScalar: DevDouble Used as high limit for the scan.
ScanIntegrationTimeScalar: DevLong Measuring time in the scan.
ScanModeScalar: DevString Mode for the SCAN: INT or WIN
ScanWinScalar: DevDouble Window used for scanning in window mode.
ScanStepSizeScalar: DevDouble Step Size
BiasSoftLimitScalar: DevDouble Software limit for the BiasSetpoint.
ScanSpectrumSpectrum: DevLong Output of the scan

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
StartCounterInput: DevVarLongArray
Counting time, number of repetitions
Output: DevVoid
Starts the counter using the internal time base. The counting time muss always be given (in us). The number of repetitions is optional (1 by default).
StartScanInput: DevVoid
Output: DevVoid
Start an scan in the threshold for integration mode measurements. It uses the attributes ScanLowLimit, ScanHighLimit, ScanNbSteps and ScanIntegrationTime
StopScanInput: DevVoid
Output: DevVoid
Stops the scan after finishing the current point.

Pipes:

Properties:

Name Description
SocketDSDevString Name of the Tango Device connecting via socket to the device
GpibDeviceNameDevString Gpib device for connecting to the device

31 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 Nov 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Jan 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:5 Jan 2018, 3:15 p.m.