PiLCArrayBasedTG - - TANGO Controls

This is historical information of device classes implemented in PiLCArrayBasedTG device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


PiLC Trigger Generator based on customized arrays

Families: OtherInstruments

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
FileToLoadScalar: DevString Full path of the file with the arrays generating the triggers
ArmScalar: DevLong Set to 1 to start triggering in counter mode, 2 in encoder mode and 0 to stop.
CurrentEncoderValueScalar: DevLong —
CurrentCounterValueScalar: DevLong —
Signal1CounterValueScalar: DevLong —
Signal1NextPointScalar: DevLong —
Signal2CounterValueScalar: DevLong —
Signal2NextPointScalar: DevLong —
Signal3CounterValueScalar: DevLong —
Signal3NextPointScalar: DevLong —
Signal4CounterValueScalar: DevLong —
Signal4NextPointScalar: DevLong —
PositionConversionScalar: DevDouble Conversion from enconder values to physical units: steps = conversion*units
CurrentPositionScalar: DevDouble —

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
LoadTriggerArraysInput: DevVoid
Output: DevVoid
Loads the data readout from the FileToLoad file to the FPGA.
CalibrateEncoderInput: DevDouble
Position to load (in physical units)
Output: DevVoid
Set encoder position to the given value (in physical units).

Pipes:

Properties:

Name Description
PiLCDeviceDevString Name of the PiLC tango device to connect to

9 Feb 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Oct 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Jan 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Jan 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Jan 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Dec 2017, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Aug 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



22 Jul 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



15 Jul 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:26 Aug 2017, 3:03 a.m.