Development status:
Released,
Release: release_3_3_9
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/SoftwareSystem/Sequencer/ScanServerV2
Contact:
Class Description
- This Device is a generic scan service for the Tango world. it allows to move
- Actuators (ie writable attributes) and to read Sensors (ie readable attributes) after a specified Integration Time
Families: SoftwareSystem
Key words: - Sequencer
Platform: All Platforms
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| dataRecorderPartialModeScalar: DevBoolean | — |
| filePathScalar: DevString | — |
| fileBaseNameScalar: DevString | — |
| fileExtensionScalar: DevString | — |
| runNameScalar: DevString | — |
| pointNumberScalar: DevLong | — |
| pointNumber2Scalar: DevLong | — |
| scanNumberScalar: DevLong | — |
| actuatorsDelayScalar: DevDouble | — |
| timebasesDelayScalar: DevDouble | — |
| manualModeScalar: DevBoolean | — |
| automaticDirectionScalar: DevBoolean | — |
| zigzagScalar: DevBoolean | — |
| onTheFlyScalar: DevBoolean | — |
| hwContinuousScalar: DevBoolean | — |
| hwContinuousNbPtScalar: DevLong | — |
| enableScanSpeedScalar: DevBoolean | — |
| scanTypeScalar: DevLong | — |
| contextValidationScalar: DevString | — |
| contextValidationErrorStrategyScalar: DevLong | — |
| actuatorsTimeOutScalar: DevDouble | — |
| actuatorsRetryCountScalar: DevLong | — |
| actuatorsRetryTimeoutScalar: DevDouble | — |
| actuatorsErrorStrategyScalar: DevLong | — |
| timebasesTimeOutScalar: DevDouble | — |
| timebasesRetryCountScalar: DevLong | — |
| timebasesRetryTimeoutScalar: DevDouble | — |
| timebasesErrorStrategyScalar: DevLong | — |
| sensorsTimeOutScalar: DevDouble | — |
| sensorsRetryCountScalar: DevLong | — |
| sensorsRetryTimeoutScalar: DevDouble | — |
| sensorsErrorStrategyScalar: DevLong | — |
| hooksTimeOutScalar: DevDouble | — |
| hooksRetryCountScalar: DevLong | — |
| hooksRetryTimeoutScalar: DevDouble | — |
| hooksErrorStrategyScalar: DevLong | — |
| afterRunActionTypeScalar: DevLong | — |
| afterRunActionSensorScalar: DevLong | — |
| afterRunActionActuatorScalar: DevLong | — |
| afterRunActionActuatorValueScalar: DevDouble | — |
| runStartDateScalar: DevString | — |
| scanStartDateScalar: DevString | — |
| scanEndDateScalar: DevString | — |
| runEndDateScalar: DevString | — |
| scanDurationScalar: DevString | — |
| runDurationScalar: DevString | — |
| scanRemainingTimeScalar: DevString | — |
| runRemainingTimeScalar: DevString | — |
| scanElapsedScalar: DevString | — |
| runElapsedScalar: DevString | — |
| runCompletionScalar: DevDouble | — |
| scanCompletionScalar: DevDouble | — |
| deadTimeScalar: DevDouble | — |
| deadTimePercentScalar: DevDouble | — |
| deadTimePerPointScalar: DevDouble | — |
| recordDataScalar: DevBoolean | — |
| dataRecordedScalar: DevBoolean | — |
| dataRecorderConfigScalar: DevString | — |
| generatedNexusFileNameScalar: DevString | — |
| versionScalar: DevString | — |
| actuatorsSpectrum: DevString | — |
| actuators2Spectrum: DevString | — |
| sensorsSpectrum: DevString | — |
| timebasesSpectrum: DevString | — |
| integrationTimesSpectrum: DevDouble | — |
| scanSpeedSpectrum: DevDouble | — |
| preRunHooksSpectrum: DevString | — |
| preScanHooksSpectrum: DevString | — |
| preStepHooksSpectrum: DevString | — |
| postActuatorMoveHooksSpectrum: DevString | — |
| postIntegrationHooksSpectrum: DevString | — |
| postStepHooksSpectrum: DevString | — |
| postScanHooksSpectrum: DevString | — |
| postRunHooksSpectrum: DevString | — |
| actuatorsDataListSpectrum: DevString | — |
| actuators2DataListSpectrum: DevString | — |
| sensorsDataListSpectrum: DevString | — |
| scanInfoSpectrum: DevString | — |
| trajectoriesImage: DevDouble | — |
| trajectories2Image: DevDouble | — |
| historicImage: DevString | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| StartInput: DevVoid Output: DevVoid |
Start the Run |
| AbortInput: DevVoid Output: DevVoid |
Abort the Run |
| PauseInput: DevVoid Output: DevVoid |
Pause the scan |
| ResumeInput: DevVoid Output: DevVoid |
Resume the scan when is Pause State |
| CleanInput: DevVoid Output: DevVoid |
None. |
| ClearHistoricInput: DevVoid Output: DevVoid |
Empty the log historic |
| ExecuteActionInput: DevVoid Output: DevVoid |
Executes the specified AfterRunAction |
Pipes:
Properties:
| Name | Description |
|---|---|
| CurrentFileBaseNameDevString | — |
| ExpertParametersString[]Type | — |
| CurrentFileExtensionDevString | — |
| CurrentFilePathDevString | — |
| DataFileActivationDevBoolean | enables the ASCII data file |
| DataFileTypeDevLong | 0 : ASCII 1 : Nexus |
| DataRecorderDevString | device name for the Nexus Data Recorder |
| DataRecorderWriteModeDevLong | 0 -> call WriteScanData in the DataRecorder device 1 -> write nexus file directly from ScanServer |
| DataRecorderSavingPeriodDevDouble | the period (in seconds) at which the DataRecorder->WriteScanData is called |
| PluginRootPathDevString | The path to the plugins directory |
| DataFitterDevString | a data fitter device to use for post scan behavior |
| SynchronizeDataDevBoolean | Enable/Disable synchronize data coming from timebase and sensor. [default = true] |
| TimeScanActuatorsDelayDevBoolean | Set it to `true` if you want to use the `actuatorsdelay` fonctionnality in case of time-scans |
| NI6602TimebaseDelayDevLong | It is sometime needed to insert a delay (ms) before starting a Ni6602 card configured in pulse generator mode |
Please log in to comment.
README
b'Introduction\n============\n\nThis is the ScanServer developed at the synchrotron Soleil, France.\nSee the AUTHORS file for a list of the authors of this project.\n\nThe ScanServer is a Tango server which can perform scans of one or many Tango attributes and record the\nsignal of one or many other attributes as a function of the scanned attributes. In order to control\ndata acquisition hardware one or more time bases can be specified which start and stop timers and\ncounters and report when a measurement has been done.\n\nThe automake/autoconf scripts assume the user wants to use NEXUS as a data format. The nexuscpp library is required\nto be installed. The Nexus data format has many advantages over text files and can be red directly by\nmany data analysis programs.\n\nThe main code of the ScanServer functionality is now contained in the ScanUtils library (including PluginGenerator).\n\n\nDirectory Structure (sources)\n=============================\n\n./: the auto-config and auto-make files, README, INSTALL, AUTHORS... files\n./doc: The original documentation from the ScanServerV2.\n./Device: The source code of the ScanServer device\n\n\nDirectory Structure (instaled files)\n====================================\n\n<prefix>/bin: ScanServer binary\n\n\n\n'