Class Description


the two-theta motion at P07 is made of a translation and rotation

Families: Motion

Key words:

Platform: All Platforms

Language: Cpp

License:

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
PositionScalar: DevDouble —
PositionSimScalar: DevDouble —
UnitLimitMinScalar: DevDouble —
UnitLimitMaxScalar: DevDouble —
FlagUseAnalyzerScalar: DevLong if flag == 0, the analyzer is not used, theta_ana = 0
FlagEnergyFromAttributeScalar: DevLong if flag == 0, the energy is read from the monochromator\ndevice, otherwise the energy attribute is read
EnergyScalar: DevDouble supplies the enery for the analyzer as long as the\nmonochromator cannot be read
D_analyzerScalar: DevDouble the lattice spacing of the analyzer
ResultSimSpectrum: DevString —

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
InitInput: DevVoid
Output: DevVoid
Re-initialise the device
ResetMotorInput: DevVoid
Output: DevVoid
—
CalibrateInput: DevDouble
Output: DevVoid
the input is a twoTheta angle, in additional input is the distance attribute, both values are used to calibrate the translation and rotation axes
StopMoveInput: DevVoid
Output: DevVoid
stops both axes

Pipes:

Properties:

Name Description
AxisTranslationDetectorDevString the axis that translates the detector
AxisRotationDetectorDevString the axis that rotates the detector
AxisRotationCollimatorDevString the axis that rotates the collimator
AxisRotationAnalyzerDevString the axis that rotates the analyzer
AxisDistanceSampleDetectorDevString —
AxisMonochromatorDevString this axis points to a monochromator, the attribute position corresponds to the energy

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.