AcqPrinceton - - TANGO Controls
.

Average: 0
Rating Count: 0

Development status: New development
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/2D/AcqPrinceton
Contact:



Class Description


Princeton CCD acquisition device

Families: Acquisition

Key words: 2D

Language: Cpp

License:

Contact:

Class interface


Attributes:

Name Description
absorptionSpectrum: DevDouble —
acqModeScalar: DevLong —
averageIntensitySpectrum: DevDouble —
checkTemperatureScalar: DevBoolean —
depthScalar: DevLong —
exposureScalar: DevDouble —
fileFormatScalar: DevString —
fileNameScalar: DevString —
fileParmsSpectrum: DevString —
framesScalar: DevLong —
heightScalar: DevLong —
imageImage: DevUShort —
intensitySpectrum: DevDouble —
intensity0Spectrum: DevDouble —
intensityBlackSpectrum: DevDouble —
numFrameScalar: DevLong —
rotateImageScalar: DevLong —
saturationScalar: DevDouble —
saturationAlarmScalar: DevDouble —
saturationMaxScalar: DevDouble —
shutterModeScalar: DevLong —
temperatureScalar: DevDouble —
timingScalar: DevDouble —
triggerScalar: DevLong —
useROIScalar: DevBoolean —
widthScalar: DevLong —
shutterCloseDelayScalar: DevDouble —
roi1xminScalar: DevLong —
roi1xmaxScalar: DevLong —
roi1yminScalar: DevLong —
roi1ymaxScalar: DevLong —
xbinScalar: DevLong —
ybinScalar: DevLong —
nbROIScalar: DevLong —
roiSpectrum: DevLong —
intensityZone1Scalar: DevDouble —
intensityZone2Scalar: DevDouble —
intensityZone3Scalar: DevDouble —
intensityZone4Scalar: DevDouble —
intensityZone5Scalar: DevDouble —
intensityZone6Scalar: DevDouble —
intensityZone7Scalar: DevDouble —
intensityZone8Scalar: DevDouble —
intensityZone9Scalar: DevDouble —
intensityZone10Scalar: DevDouble —
intensityZone11Scalar: DevDouble —
intensityZone12Scalar: DevDouble —
intensityNbZonesScalar: DevLong —
binningSpectrum: DevLong —

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
AcquireIntensity0Input: DevVoid
Output: DevVoid
Sets the intensity0 attribute with the latest measured intensity
AcquireIntensityBlackInput: DevVoid
Output: DevVoid
Sets the intensityBlack attribute with the latest measured intensity
CloseInput: DevVoid
Output: DevVoid
Frees the current camera, prepares it for power-down
GetParamInput: DevString
Output: DevString
None.
OpenInput: DevVoid
Output: DevVoid
Reserves and initializes the camera hardware - Detects the characteristics of the CCD : width, height, depth wich can be read using the device`s attributes - Sets the desired temperature
ResetIntensityBlackInput: DevVoid
Output: DevVoid
None.
SetParamInput: DevVarStringArray
Output: DevVoid
None.
StartInput: DevVoid
Output: DevVoid
Starts exposing - the desired exposing mode (continuous or sequence) must be previously defined with SetMode() command
StopInput: DevVoid
Output: DevVoid
Stops the current sequence of exposing

Pipes:

Properties:

Name Description
CamIdDevString Camera identifier
CamTypeDevLong Camera type 0 = Princeton


Please log in to comment.

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 9:08 a.m.