MythenRoIs - - TANGO Controls

This is historical information of device classes implemented in MythenRoIs device server.

Use this link to find the valid information.

Development status: Released
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/1D/MythenRoIs
Contact:



Class Description


Mythen detector with RoIs as counters

Families: Acquisition

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
Counts1Scalar: DevDouble Counts in RoI1
Counts2Scalar: DevDouble Counts in RoI2
FileDirScalar: DevString —
FilePrefixScalar: DevString —
FileIndexScalar: DevLong —
ExposureTimeScalar: DevDouble —
DoorNameScalar: DevString Name of the Door to connect to.
ConnectionToDoorScalar: DevLong 1 if connected to door in DoorName attribute 0 if not connected to any door 2 if connected to a door different from the one in DoorName
ScanIDScalar: DevDouble Number of the ScanID read from the Door. -1 if not door connection
CountsTotalScalar: DevDouble Counts in complete detector
CountsMaxScalar: DevDouble Maximum intensity
LastImageScalar: DevString Name (including directory path) of the last image saved.
RoI1Spectrum: DevLong Limits for RoI
RoI2Spectrum: DevLong Limits for RoI

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartAcquisitionInput: DevVoid
Output: DevVoid
—
ConnectToDoorInput: DevVoid
Output: DevVoid
—
ResetConnectionToDoorInput: DevVoid
Output: DevVoid
Set ConnectionToDoor to 0 for working independent of sardana scan settings

Pipes:

Properties:

Name Description
SLSSoftVersionDevLong 0 -> old sls software (cl commands starting with mythen_) 1 -> new sls software (cl commands starting with sls_detector_) 2 -> new sls software with also id argument
MythenIDDevLong ID of the mythen detector (used in the cl commands). Not needed for SLSSoftVersion 1

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 9:05 a.m.