Class Description


This device server is intended to drive a Varian Dual ion pump controller.

Families: Vacuum

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: Varian

Bus: Serial Line

Class interface


Attributes:

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
AddPumpInput: DevShort
Channel number
Output: DevVoid
Add a pump to be controlled.\nThe controller thread will initialize the specified pump and then control it.
ChangeSetpointInput: DevVarFloatArray
argin[0] = channel number coded as a float.\nargin[1] = setpoint value.\nargin[2] = 1 for first step current - 2 for second step current.
Output: DevVoid
Change the setpoint of specified channel, and specified current
GetChannelStateInput: DevShort
The channel number
Output: State
Get the considered channel state ("ON" or "OFF").
GetChannelStatusInput: DevShort
The channel number
Output: DevString
Get the status of the considered channel.
GetControlTypeInput: DevVoid
Output: DevString
The controller control type
Read the type of control of the controller ("remote" or "local").
GetSizeInput: DevShort
The channel number.
Output: DevString
The pump size
Return the pump size.
GetVersionInput: DevVoid
Output: DevString
The firmware version string.
Get the controller firmware version.
IsInitializedInput: DevShort
Channel number.
Output: DevBoolean
return true if specified pump is nitialized.
LocalInput: DevVoid
Output: DevVoid
Set the controller to local mode (operated from front panel).
OffInput: DevShort
The channel number.
Output: DevVoid
Set to OFF the considered channel.
OnInput: DevShort
The channel number.
Output: DevVoid
Set to ON the considered channel.
ReadCurrentInput: DevShort
The channel number
Output: DevFloat
The current value
Get the measure current value of the considered channel.
ReadFixedModeInput: DevShort
Channel number
Output: DevBoolean
Returns TRUE if the pump is in FIXED mode, FALSE if the mode is STEP.
ReadImaxInput: DevShort
The channel number
Output: DevLong
Read the imax of the considered channel.
ReadIprotectInput: DevShort
The channel number
Output: DevLong
Read the iprotect of the considered channel.
ReadIstep1Input: DevShort
The channel number
Output: DevFloat
Read the istep1 of the considered channel.
ReadIstep2Input: DevShort
The channel number
Output: DevFloat
Read the istep2 of the considered channel.
ReadPressureInput: DevShort
The channel number.
Output: DevFloat
Read the pressure of the considered channel.
ReadStartModeInput: DevShort
Channel number
Output: DevBoolean
Returns TRUE if the pump is in START mode, FALSE if the mode is PROTECT
ReadStateInput: DevShort
The channel number
Output: State
The state of the channel
Get the state of the considered channel.
ReadVmaxInput: DevShort
The channel number
Output: DevLong
Read the Vmax of the considered channel.
ReadVoltageInput: DevShort
The channel number
Output: DevFloat
The voltage value
Get the measure voltage value of the considered pump.
ReadVstep1Input: DevShort
The channel number
Output: DevLong
Read the vstep1 of the considered channel.
ReadVstep2Input: DevShort
The channel number
Output: DevLong
Read the vstep2 of the considered channel.
RemoteInput: DevVoid
Output: DevVoid
Set the controller to the remote mode (operated using the serial line).
SetFixedModeInput: DevShort
The channel number
Output: DevVoid
Set the considered channel to the fixed mode.
SetMaxVoltageInput: DevVarShortArray
The channel number.
Output: DevVoid
Set the max voltage for the considered channel. - argin[0] = channel number - argin[1] = max voltage value
SetProtectModeInput: DevShort
The channel number
Output: DevVoid
Set the considered channel to the protect mode.
SetStartModeInput: DevShort
The channel number
Output: DevVoid
Set the considered channel to the start mode.
SetStepModeInput: DevShort
The channel number
Output: DevVoid
Set the considered channel to the step mode.
GetControllerInput: DevVoid
Output: DevString
type of contoller
get the type on Controller

Pipes:

Properties:

Name Description
SerialDeviceNameDevString The name of the associated serial line device.

Class Description


This device server is intended to drive and monitor a ion pump controlled by a Varian Dual ion pump controller. You need VarianDualCrtl device classes OR Agilent4uhv device classes

Families: Vacuum

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: Varian

Product:

Dual IP

Bus: Serial Line

Class interface


Attributes:

Name Description
PressureScalar: DevFloat —
VoltageScalar: DevFloat —
CurrentScalar: DevFloat —
SizeScalar: DevString —
ControlTypeScalar: DevString —
FirstStepCurrentScalar: DevFloat —
SecondStepCurrentScalar: DevFloat —
FixModeScalar: DevBoolean —
StartModeScalar: DevBoolean —
ControllerScalar: DevString —

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
OffInput: DevVoid
Output: DevVoid
Set the pump to OFF.
OnInput: DevVoid
Output: DevVoid
Set the pump to ON.
SetFixedModeInput: DevVoid
Output: DevVoid
Set the pump channel to the "fixed" mode.
SetStartModeInput: DevVoid
Output: DevVoid
Set the pump channel to the "start" mode.
SetStepModeInput: DevVoid
Output: DevVoid
Set the pump channel to the "step" mode.
SetProtectModeInput: DevVoid
Output: DevVoid
Set the pump channel to the "protect" mode.

Pipes:

Properties:

Name Description
ChannelNumberDevShort The channel number of the ion pump (1 or 2)
ControllerDeviceNameDevString The device name of the associated ion pump controller

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.



3 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



3 Jan 2017, Piotr Goryl
Created: