tpg256a - - TANGO Controls

This is historical information of device classes implemented in tpg256a device server.

Use this link to find the valid information.

Development status: New development
Information status: New

Contact:



Class Description


Total pressure gauge and controller

Families: Vacuum

Key words:

Platform: All Platforms

Language: Cpp

License:

Contact:

Hardware


Manufacturer: Pfeiffer

Product:

Tpg 256 a

Bus: Serial Line

Class interface


Attributes:

Name Description
Name_0Scalar: DevString —
Name_1Scalar: DevString —
Name_2Scalar: DevString —
Name_3Scalar: DevString —
Name_4Scalar: DevString —
Name_5Scalar: DevString —
Pressure_0Scalar: DevDouble —
Pressure_1Scalar: DevDouble —
Pressure_2Scalar: DevDouble —
Pressure_3Scalar: DevDouble —
Pressure_4Scalar: DevDouble —
Pressure_5Scalar: DevDouble —
State_0Scalar: DevState —
State_1Scalar: DevState —
State_2Scalar: DevState —
State_3Scalar: DevState —
State_4Scalar: DevState —
State_5Scalar: DevState —
Status_0Scalar: DevString —
Status_1Scalar: DevString —
Status_2Scalar: DevString —
Status_3Scalar: DevString —
Status_4Scalar: DevString —
Status_5Scalar: DevString —
DeviceStateScalar: DevUChar —
SetPointStatusSpectrum: DevBoolean —

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
SensorOnInput: DevShort
Channel [0,5]
Output: DevVoid
Start measuring channel n
SensorOffInput: DevShort
Channel [0,5]
Output: DevVoid
Stop measuring channel n
WriteLowerThresholdInput: DevVarDoubleArray
Setpoint, Pressure Setpoint 0 -> Switching function A 1 -> Switching function B 2 -> Switching function C 3 -> Switching function D 4 -> Switching function E 5 -> Switching function F Pressure [1.0E-11, 9.9E+3]
Output: DevVoid
Set setpoint lower threshold
ReadLowerThresholdInput: DevShort
Setpoint 0 -> Switching function A 1 -> Switching function B 2 -> Switching function C 3 -> Switching function D 4 -> Switching function E 5 -> Switching function F
Output: DevDouble
Pressure
Get setpoint lower threshold
WriteUpperThresholdInput: DevVarDoubleArray
Setpoint, Pressure Setpoint 0 -> Switching function A 1 -> Switching function B 2 -> Switching function C 3 -> Switching function D 4 -> Switching function E 5 -> Switching function F Pressure [1.0E-11, 9.9E+3]
Output: DevVoid
Set setpoint upper threshold
ReadUpperThresholdInput: DevShort
Setpoint 0 -> Switching function A 1 -> Switching function B 2 -> Switching function C 3 -> Switching function D 4 -> Switching function E 5 -> Switching function F
Output: DevDouble
Pressure
Get setpoint upper threshold
ReadSensorSourceInput: DevShort
Setpoint 0 -> Switching function A 1 -> Switching function B 2 -> Switching function C 3 -> Switching function D 4 -> Switching function E 5 -> Switching function F
Output: DevShort
Source 0 -> Measuring circuit 0 1 -> Measuring circuit 1 2 -> Measuring circuit 2 3 -> Measuring circuit 3 4 -> Measuring circuit 4 5 -> Measuring circuit 5
Get setpoint source
WriteSensorSourceInput: DevVarShortArray
Setpoint, Source Setpoint 0 -> Switching function A 1 -> Switching function B 2 -> Switching function C 3 -> Switching function D 4 -> Switching function E 5 -> Switching function F Source: 0 -> Measuring circuit 0 1 -> Measuring circuit 1 2 -> Measuring circuit 2 3 -> Measuring circuit 3 4 -> Measuring circuit 4 5 -> Measuring circuit 5
Output: DevVoid
Set setpoint switching function
RegisterNameInput: DevVarLongStringArray
Channel, Name Channel [0,5] Name max 64 characters
Output: DevVoid
Set channel name
UnregisterNameInput: DevShort
Channel [0,5]
Output: DevVoid
Unregister channel name

Pipes:

Properties:

Name Description
SerialDeviceDevString —
TimeoutDevULong Milliseconds
ThreadSleepDevULong Millisecond
ProxySleepDevULong Millisecond

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.



3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:19 Jan 2017, 10:55 a.m.