Danfysik_9100 - - TANGO Controls

This is historical information of device classes implemented in Danfysik_9100 device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


This device has been developed to prepare a testbench for Danfysik 9100 device server.

Families: Simulators

Key words:

Platform: All Platforms

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
SimulateSerialFailScalar: DevBoolean —

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
DevSerFlushInput: DevLong
flush to do 0=input 1=output 2=both
Output: DevVoid
—
DevSerreadRawInput: DevVoid
Output: DevString
pointer to the string read updated
—
DevSerWriteStringInput: DevString
String to write
Output: DevLong
Number of characters written
—

Pipes:

Properties:

Class Description


The tailor is rich and my mother is in the kitchen.

Families: PowerSupply

Key words:

Platform: All Platforms

Language: Python

License:

Contact:

Hardware


Manufacturer: Danfysic

Product:

9100

Bus: Not Applicable

Class interface


Attributes:

Name Description
CurrentScalar: DevDouble —
CurrentSetpointScalar: DevDouble —
VoltageScalar: DevDouble —
CurrentSlewrateScalar: DevDouble —
AmbientTemperatureScalar: DevDouble —
StateCode64Scalar: DevLong64 —
RemoteModeScalar: DevBoolean —
ErrorsSpectrum: DevString —

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
OffInput: DevVoid
Output: DevVoid
—
OnInput: DevVoid
Output: DevVoid
—
ResetInterlocksInput: DevVoid
Output: DevVoid
—
UpdateStatusInput: DevVoid
Output: DevVoid
—
ReadADInput: DevShort
Output: DevString
—

Pipes:

Properties:

Name Description
SerialLineDevString The serial line to be used

23 Feb 2017, Piotr Goryl
Updated:
A device class has been added.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.



3 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:19 Jan 2017, 10:51 a.m.