This is historical information of device classes implemented in MHzDAQp01 device server.

Use this link to find the valid information.

Development status: Released
Information status: New

Contact:



Class Description


MHz DAQ System via TCP connection

Families: Acquisition

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: TCP/UDP

Class interface


Attributes:

Name Description
FilePrefixScalar: DevString File prefix, used by the Start command.
NbTriggersScalar: DevDouble Number of acquistions to take. The acquistion will stop after these number of acquistions is taken.
FileNumScalar: DevLong Number added to FilePrefix for creating the file name sent with the Start command to the MHz DAQ. This number is reset to 0 every time the FilePrefix is written and it increments automatically when the Start command is called.

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartInput: DevVoid
Output: DevVoid
Starts acquisition. It uses attributes FilePrefix and NbTriggers
StopInput: DevVoid
Output: DevVoid
Stops acquisition
CloseRunLoopInput: DevVoid
Output: DevVoid
terminates the run loop of the TCP server, so that it can be shutdown from the Karabo CLI.
ReadChannelInput: DevVarLongArray
Channel number, laser/nolaser (0,1), mean/std dev(0,1)
Output: DevDouble
Requested value
Read mean value or standard desviation for a given channel with or without laser.

Pipes:

Properties:

Name Description
HostNameDevString Name of the host
PortNbDevLong Port number
SimulationModeDevLong 1 if simulation mode

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:19 Jan 2017, 10:50 a.m.