SmarActMCSCtrl - - TANGO Controls

This is historical information of device classes implemented in SmarActMCSCtrl device server.

Use this link to find the valid information.

Development status: Released
Information status: New

Contact:



Class Description


Controller device server for Smaract Modular Control System

Families: Motion

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: Smaract

Product:

Bus: Ethernet

Class interface


Attributes:

Name Description
SensorsEnabledScalar: DevULong 0: SENSOR_DISABLED 1: SENSOR_ENABLED 2: SENSOR_POWERSAVE
HandControlScalar: DevULong Enable / disable hand control module: 0: hand control disabled 1: hand control enabled 2: hand control disabled, but position data will be displayed

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
CalibrateSensorInput: DevULong
Axis number (0-2)
Output: DevVoid
—
HomeInput: DevVarULongArray
0: Axis number 1: direction 2: holdTime 3: autoZero
Output: DevVoid
—
AxisStateInput: DevULong
Axis number
Output: DevULong
Axis status
—
GetPositionInput: DevULong
Axis number
Output: DevLong
Position
—
SetPositionInput: DevVarLongArray
0: Axis number 1: target position
Output: DevVoid
—
PositionKnownInput: DevULong
Axis number
Output: DevBoolean
true if position is known, false if not
—
SetMaxFrequencyInput: DevVarULongArray
Output: DevVoid
—
GetLimitInput: DevULong
Axis number
Output: DevVarLongArray
0: lower limit 1: upper limit
—
SetLimitInput: DevVarLongArray
0: Axis number 1:lower limit 2: upper limit
Output: DevVoid
—
SetAccelerationInput: DevVarULongArray
Output: DevVoid
—
SetSpeedInput: DevVarULongArray
Output: DevVoid
—
GetAccelerationInput: DevULong
Output: DevULong
—
GetSpeedInput: DevULong
Output: DevULong
—
StopInput: DevULong
Axis number
Output: DevVoid
—
CalibrateInput: DevVarLongArray
0: axis number 1: value to calibrate to
Output: DevVoid
—
GetAxisTypeInput: DevULong
Axis number
Output: DevULong
Axis type: 0: linear 1: rotary 2: goniometer
—
GetSensorTypeInput: DevULong
Axis number
Output: DevULong
Encoder type number (check with hardware docs)
—

Pipes:

Properties:

Name Description
HostNameDevString Hostname / IP address of device
PortNumberDevString —

16 Mar 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 Feb 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Jan 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:19 Jan 2017, 10:48 a.m.