Development status:
Released,
Release: Release_1_3
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/BeamlineComponents/AnalyzerEP01
Contact:
Class Description
- Changes the energy of the analyzer detector system as a combined
- movement of three motors.
Families: Motion
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| CrystalSpacingScalar: DevDouble | Analyzer crystal spacing. |
| RowlandScalar: DevDouble | Rowland circle radius |
| FakeNumberScalar: DevDouble | Parameter that can vary for keeping analyzer and detector angles in sync. |
| PositionScalar: DevDouble | Analyzer Energy |
| UnitLimitMaxScalar: DevDouble | — |
| UnitLimitMinScalar: DevDouble | — |
| PositionSimScalar: DevDouble | — |
| DetThetaOffsetScalar: DevDouble | Offset to be added to the DetTheta calculation |
| ResultSimSpectrum: DevString | Show the motor positions for the energy written in PositionSim |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| CalibrateInput: DevDouble Value to be calibrated Output: DevVoid |
— |
| StopMoveInput: DevVoid Output: DevVoid |
Stop the three motors. |
Pipes:
Properties:
| Name | Description |
|---|---|
| AnalyzerThetaDevString | Name of the analyzer_theta Tango device |
| AnalyzerZDevString | Name of the analyzer_z Tango device. |
| DetThetaDevString | Name of the det_theta Tango device. |
| DetZDevString | Name of the det_z Tango device. |
Please log in to comment.
Generated
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.