Development status:
Released,
Release: Release_1_0
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/1D/Gotthard
Contact:
Class Description
This project provides a tango server for Gotthard detector.
Families: Acquisition
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: PSI
Product:
Gotthard
Bus: Data Socket
Class interface
Attributes:
| Name | Description |
|---|---|
| ConfigFileNameScalar: DevString | Name of the configure file. |
| CyclesScalar: DevShort | the number of cycles(e.g. number of triggers) The total number of images will be frames times cycles. |
| DelayAfterTriggerScalar: DevLong | the delay after trigger in triggerd mode |
| DetectorTypeScalar: DevString | Detector Type,e.g. Gotthard |
| DynamicRangeScalar: DevShort | the dynamic range(in bits) of the data for a photon counting detector |
| ExposureTimeScalar: DevFloat | Exposure time for each frame. |
| FlatFieldCorrectionFilePathScalar: DevString | — |
| FlatFieldCorrectionFileNameScalar: DevString | — |
| FramesScalar: DevULong | number of frames i.e. number of exposure per trigger |
| GatesScalar: DevShort | Number of gates per frame in gated mode. |
| OutDirScalar: DevString | The directory to which the files will be written by default. |
| OutFileIndexScalar: DevLong | The start index of the output files (automatically incremented by the acquisition functions). |
| OutFileNameScalar: DevString | output file name |
| PeriodScalar: DevLong | frame period in s |
| SettingsScalar: DevShort | settings ( 6:veryhighgain, 2:highgain, 5:mediumgain, 4:lowgain, 3:dynamicgain ) |
| ThresholdScalar: DevShort | Threshold energy |
| TimingModeScalar: DevShort | sets the timing mode of the detector can be: auto,gating,trigger,ro_trigger,triggered_gating |
| SetupFileNameScalar: DevString | — |
| FlatFieldCorrectionEnabledScalar: DevBoolean | enable flat file correction |
| LastestDataSpectrum: DevUChar | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| ReadConfigInput: DevVoid Output: DevVoid |
Read the configurations from file. |
| ReadSetupFromFileInput: DevVoid Output: DevVoid |
loads the detector setup from file. |
| SaveSetupToFileInput: DevVoid Output: DevVoid |
reads the parameters from the detector and writes them to file. |
| StartAcqInput: DevVoid Output: DevVoid |
— |
| StopAcqInput: DevVoid Output: DevVoid |
— |
| RefreshInput: DevVoid Output: DevVoid |
Refresh all the parameters of the detector |
Pipes:
Properties:
| Name | Description |
|---|---|
| DetectorIdDevUShort | — |
| SimulationModeDevUShort | — |
Please log in to comment.