Development status:
Released,
Release: Release_1_0
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MagneticDevices/CryogenicVectorMagnet
Contact:
Class Description
Control of the Vector Magnet system from Cryogenic.
Families: MagneticDevices
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: Cryogenic
Product:
Vector Magnet System J3901
Bus: Socket
Class interface
Attributes:
| Name | Description |
|---|---|
| LS350HeatPowerAScalar: DevDouble | Get heater output |
| LS350SensCScalar: DevDouble | Set target temperature for sensor C. Get current temperature of sensor C. |
| LS350SensDScalar: DevDouble | Set target temperature for sensor D. Get current temperature of sensor D. |
| FieldXScalar: DevDouble | Field in the X direction |
| FieldYScalar: DevDouble | Field in the Y direction |
| FieldZScalar: DevDouble | Field in the Z direction |
| TimeToTargetScalar: DevDouble | Time to target. It is limited by the slowest ramp rate. |
| RampRateXScalar: DevDouble | Ramp rate of X power supply |
| RampRateYScalar: DevDouble | Ramp rate of Y power supply |
| RampRateZScalar: DevDouble | Ramp rate of Z power supply |
| DirRotScalar: DevLong | Set rotation direction (0-> clockwise, 1 -> anti-clockwise). Reads last set value. |
| ModeScalar: DevLong | Set coordinate mode (0->cartesian, 1->spherical). Reads last set value. |
| FieldMagnitudeScalar: DevDouble | Set field magnitude (only for spherical mode). Reads last set value. |
| ThetaScalar: DevDouble | Set theta angle (only for spherical mode). Reads last set value. |
| PhiScalar: DevDouble | Set phi angle (only for spherical mode). Reads last set value. |
| FindTimeScalar: DevLong | Enables/disables an iteration routine (during setCalculatePath) that finds the time needed to ramp to the set field at the ramp rate. |
| PersistentModeScalar: DevLong | Set the power supplies to persistent mode. Reads last set value. |
| HeaterStateScalar: DevLong | Gets the state of the heater to indicate wether the magnet is in persistent mode. |
| LS350SensAScalar: DevDouble | Set target temperature for sensor A. Get current temperature of sensor A. |
| LS350SensBScalar: DevDouble | Set target temperature for sensor B. Get current temperature of sensor B. |
| LS350HeatPowerBScalar: DevDouble | Get heater output |
| LS350HeatPowerCScalar: DevDouble | Get heater output |
| LS350HeatPowerDScalar: DevDouble | Get heater output |
| LS218SensorTempSpectrum: DevDouble | Values of temperature sensors from the LS218 from channels 1-16 |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| AbortInput: DevVoid Output: DevVoid |
Abort current ramp or path calculation |
| CalculatePathInput: DevVoid Output: DevVoid |
Calculates the ramp path based on the TimeToTarget. |
| LS350SetOut1toSensAInput: DevVoid Output: DevVoid |
Set Heater1 (output 1) to control to Target Sensor A on the LS350. |
| LS350SetOut2toSensBInput: DevVoid Output: DevVoid |
Set Heater2 (output 2) to control to Target Sensor B on the LS350. |
| LS350SetOut3toSensCInput: DevVoid Output: DevVoid |
Set Heater3 (output 3) to control to Target Sensor C on the LS350. |
| LS350SetOut4toSensDInput: DevVoid Output: DevVoid |
Set Heater4 (output 4) to control to Target Sensor D on the LS350. |
Pipes:
Properties:
| Name | Description |
|---|---|
| IPAdressDevString | IP Adress |
| PortNbDevLong | Port Number |
Please log in to comment.