Fluke8845A - - TANGO Controls

This is historical information of device classes implemented in Fluke8845A device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


Class for controlling the digital multimeter 8845A from Fluke

Families: MeasureInstruments

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: Fluke

Product:

8845A

Bus: Ethernet

Class interface


Attributes:

Name Description
VoltageScalar: DevDouble Measured voltage
VoltageRangeScalar: DevDouble Set voltage range
SamplesPerTriggerScalar: DevLong —
NbTriggersScalar: DevLong —
TriggerSourceScalar: DevString IMM, BUS or EXT
DataSpectrum: DevDouble —

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
SendCommandInput: DevString
Output: DevString
Send a command and get an answer
SetRemoteInput: DevLong
0 -> local, 1 -> remote
Output: DevVoid
—
TriggerInput: DevVoid
Output: DevVoid
Causes the meter to trigger a measurement when parsed

Pipes:

Properties:

Name Description
IPAddressDevString —
PortNbDevLong —

3 Sep 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 Jul 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Jul 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Jul 2022, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



9 Jul 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



2 Jul 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Jun 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Jun 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Jun 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Jun 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



21 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



14 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



7 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



2 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



19 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



12 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Feb 2022, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:16 Jul 2022, 3:24 a.m.