CenterThree - - TANGO Controls

This is historical information of device classes implemented in CenterThree device server.

Use this link to find the valid information.

Development status: Released, Release: Release_2_1
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/SampleEnvironment/CenterThree
Contact:



Class Description


Families: Instrumentation

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
PressureScalar: DevDouble —
SP1Spectrum: DevDouble —
SP2Spectrum: DevDouble —
SP3Spectrum: DevDouble —
SP4Spectrum: DevDouble —
SP5Spectrum: DevDouble —
SP6Spectrum: DevDouble —
SPSSpectrum: DevBoolean Read switching function status: 0: status of switching function 1 1: status of switching function 2 2: status of switching function 3 3: status of switching function 4 4: status of switching function 5 5: status of switching function 6 0 = off, 1 = on
HVCSpectrum: DevBoolean High vacuum circuit status: 0: status of sensor 1 1: status of sensor 2 2: status of sensor 3 0 = off, 1 = on

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.

Pipes:

Properties:

Name Description
ControllerDevString The CenterThreeCtrl device
ChannelDevLong Channel number

5 Mar 2022, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



18 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Mar 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



8 Sep 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Mar 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:5 Mar 2022, 4:19 a.m.