This is historical information of device classes implemented in PowerSupplyRSHMP2020 device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Contact:
Class Description
Controlling the RandS HMP 2020 PowerSupply
Families: PowerSupply
Key words:
Platform: All Platforms
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: Rhode & Schwarz
Product:
HMP2020
Bus: USB
Class interface
Attributes:
| Name | Description |
|---|---|
| ChannelScalar: DevLong | Selected channel |
| VoltageScalar: DevDouble | Set/read voltage |
| VoltageStepSizeScalar: DevDouble | Used as step size by the RampUp/Down Voltage commands |
| CurrentScalar: DevDouble | Set/read current |
| CurrentStepSizeScalar: DevDouble | Used as step size by the RampUp/Down Current commands |
| ChannelActiveScalar: DevLong | Activatechannel and output |
| FuseScalar: DevLong | Activate/deactivate fuse |
| FuseDelayScalar: DevLong | — |
| ARBRepetitionRateScalar: DevLong | Sets the repetition rate for the arbitrary waveform for the selected channel. If set to 0, the waveform is repited infinitely. |
| ARBFilePathScalar: DevString | Path for file with input data for ARB |
| ARBFileNameScalar: DevString | File with input data for ARB |
| ARBChannelScalar: DevLong | Channel used by the ARB commands |
| ARBMemoryScalar: DevLong | Memory used by the ARB commands |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| RampUpVoltageInput: DevVoid Output: DevVoid |
Increase voltage in step size given by the attribute VoltageStepSize |
| RampDownVoltageInput: DevVoid Output: DevVoid |
Decrease voltage in step size given by the attribute VoltageStepSize |
| RampUpCurrentInput: DevVoid Output: DevVoid |
Increase current in step size given by the attribute CurrentStepSize |
| RampDownCurrentInput: DevVoid Output: DevVoid |
Decrease current in step size given by the attribute CurrentStepSize |
| SetVoltageAndCurrentInput: DevString Output: DevVoid |
Sets the voltage and current value of the selected channel |
| ActivateAllOutputsInput: DevVoid Output: DevVoid |
— |
| ARBClearInput: DevVoid Output: DevVoid |
Deletes the arbitrary waveform data of the selected channel. |
| ARBLoadDataInput: DevVoid Output: DevVoid |
Defines the arbitrary voltage, current and time value points for the selected channel from the file ARBFilePath/ARBFileName The file format has to have the format: v1,c1.t1,v2,c2,t2,... or in lines v1,c1,t1, v2,c2,t2, ... |
| ARBLoadDataFromMemoryInput: DevVoid Output: DevVoid |
Loads a saved arbitrary waveform from the internal memory selected in ARBMemory |
| ARBSaveDataToMemoryInput: DevVoid Output: DevVoid |
Saves the arbitrary waveform data in the internal memory. Up to three waveforms can be saved in the internal memory selected in ARBMemory |
| ARBStartInput: DevVoid Output: DevVoid |
Starts the arbitrary sequence in the selected channel. |
| ARBStopInput: DevVoid Output: DevVoid |
Stops the arbitrary sequence in the selected channel. |
| ARBTransferInput: DevVoid Channel (1, 2, 3 or 4) Output: DevVoid |
Transfers the defined arbitrary points to the selected channel. |
Pipes:
Properties:
| Name | Description |
|---|---|
| SerialPortDevString | USB serial port, ex. /dev/ttyUSB0 |
Updated:
The device class has been updated.
You can see previous version here .
15 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
8 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
1 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
25 Dec 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
18 Dec 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
11 Dec 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
4 Dec 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
27 Nov 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
20 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
13 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
6 Nov 2021, DS Admin
Created:
The device class has been added to catalogue.