PiLCVFCADCSingle - - TANGO Controls

This is historical information of device classes implemented in PiLCVFCADCSingle device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


VFCADC implemented in PiLC

Families: CounterTimer

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
CountsScalar: DevDouble —
ValueScalar: DevDouble —
AutoResetScalar: DevLong 0 -> auto reset off, 1 -> counts automatically reset

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
ResetInput: DevVoid
Output: DevVoid
Reset counts in PILC

Pipes:

Properties:

Name Description
PiLCDeviceDevString Name of the PiLC Tango device to connect to.
ChannelDevLong 1 to 6

20 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Nov 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



30 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



2 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 Aug 2021, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:6 Nov 2021, 3:26 a.m.