LKS336TempCtrl - - TANGO Controls

This is historical information of device classes implemented in LKS336TempCtrl device server.

Use this link to find the valid information.

Development status: Released
Information status: Updated

Contact:



Class Description


Class for controlling the Lake Shore Model 336 Temperature Controller

Families: Instrumentation

Key words:

Platform: All Platforms

Language: Cpp

License:

Contact:

Hardware


Manufacturer: none

Bus: GPIB

Class interface


Attributes:

Name Description
OutputChannelAScalar: DevDouble —
SensorTypeAScalar: DevLong Sensor Type: 0->disabled,1->Diode,2->Platinum RTD,3->NTC RTD,4->Thermocouple
SensorTypeAInfoScalar: DevString —
InputCurveAScalar: DevLong Input Curve for channel A.
TlimitAScalar: DevLong A temperature limit in Kelvin for which to shutdown all control outputs when exceeded. 0-> turns this feature off.
OutputChannelBScalar: DevDouble —
SensorTypeBScalar: DevLong Sensor Type: 0->disabled,1->Diode,2->Platinum RTD,3->NTC RTD,4->Thermocouple
SensorTypeBInfoScalar: DevString —
InputCurveBScalar: DevLong Input Curve for channel B.
TlimitBScalar: DevLong A temperature limit in Kelvin for which to shutdown all control outputs when exceeded. 0-> turns this feature off.
OutputChannelCScalar: DevDouble —
SensorTypeCScalar: DevLong Sensor Type: 0->disabled,1->Diode,2->Platinum RTD,3->NTC RTD,4->Thermocouple
SensorTypeCInfoScalar: DevString —
InputCurveCScalar: DevLong Input Curve for channel C,
TlimitCScalar: DevLong A temperature limit in Kelvin for which to shutdown all control outputs when exceeded. 0-> turns this feature off.
OutputChannelDScalar: DevDouble —
SensorTypeDScalar: DevLong Sensor Type: 0->disabled,1->Diode,2->Platinum RTD,3->NTC RTD,4->Thermocouple
SensorTypeDInfoScalar: DevString —
InputCurveDScalar: DevLong Input Curve for channel D,
TlimitDScalar: DevLong A temperature limit in Kelvin for which to shutdown all control outputs when exceeded. 0-> turns this feature off.
ResistanceH1Scalar: DevLong 1->25Ohms, 2->50Ohms
ControlModeH1Scalar: DevLong 0= Off 1= Close loop PID 2= Zone 3= Open loop 4= Monitor out 5= Warmup supply
ControlModeH1InfoScalar: DevString —
ControlChannelH1Scalar: DevLong 0->none,1->A,2->B,3->C,4->D
ProportionalH1Scalar: DevFloat Proportional parameter (also called gain).
IntegralH1Scalar: DevFloat Integral parameter (also called reset).
DerivativeH1Scalar: DevLong Derivative parameter (also called rate).
SetPointH1Scalar: DevDouble Temperature Setpoint
RampRateH1Scalar: DevDouble —
HeaterRangeH1Scalar: DevLong Heater Range: 0 to 5.
ControlModeH2Scalar: DevLong 0= Off 1= Close loop PID 2= Zone 3= Open loop 4= Monitor out 5= Warmup supply
ControlModeH2InfoScalar: DevString —
ControlChannelH2Scalar: DevLong 0->none,1->A,2->B,3->C,4->D
ProportionalH2Scalar: DevFloat Proportional parameter (also called gain).
IntegralH2Scalar: DevFloat Integral parameter (also called reset).
DerivativeH2Scalar: DevLong Derivative parameter (also called rate).
SetPointH2Scalar: DevDouble Temperature Setpoint
RampRateH2Scalar: DevDouble —
HeaterRangeH2Scalar: DevLong Heater Range: 0 to 5.
TmaxScalar: DevDouble Attribute only to write and read.
RampOffOnH1Scalar: DevLong —
RampOffOnH2Scalar: DevLong —
ResistanceH2Scalar: DevLong 1->25Ohms, 2->50Ohms
CurvesInfoSpectrum: DevString Information about curves and the allowed sensor types and temperature ranges.

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.

Pipes:

Properties:

Name Description
ControlerDeviceDevString Name of the controller device, can be a GpibDeviceServer SocketDevice Prologixadapter When using Prologixadapter, you will have to set the GpipID.
GpibIDDevLong Gpib device address when using a prologix adapter

25 Jun 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 Oct 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



27 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:30 Oct 2021, 4:35 a.m.