This is historical information of device classes implemented in QudisAxis device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


Tango device for qudis interferometer axis

Families: MeasureInstruments

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: https://www.qutools.com/

Product:

Bus: Not Applicable

Class interface


Attributes:

Name Description
StreamRelativePositionScalar: DevBoolean Tell controller to include / exclude relative position of this axis in the stored stream files.
PositionRelativeScalar: DevDouble Relative position of this axis.
AlignmentSpectrum: DevLong Shows interferogram for this axis.

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
ResetRelativePositionInput: DevVoid
Output: DevVoid
resets the relative position of this axis

Pipes:

Properties:

Name Description
AxisNumberDevLong Number of axis (0-2)
QudisControllerDevString Name of QudisController device
DynAttrListArray of DevString for internal use only

2 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 Aug 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



21 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



14 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



7 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



31 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



3 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



19 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



12 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



29 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



15 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



8 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



1 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



3 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Mar 2021, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:28 Aug 2021, 3:44 a.m.