PiezoPiC867Motor - - TANGO Controls

This is historical information of device classes implemented in PiezoPiC867Motor device server.

Use this link to find the valid information.

Development status: Released, Release: Release_1_1
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Motion/MotorControllers/PI/PiezoPiC867Motor
Contact:



Class Description


Class for the axis of the C867 piezo controller from PI

Families: Motion

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: PI

Product:

C867

Bus: Serial Line

Class interface


Attributes:

Name Description
PositionScalar: DevDouble —
UnitLimitMinScalar: DevDouble —
UnitLimitMaxScalar: DevDouble —
SlewRateScalar: DevDouble Close loop velocity
AccelerationScalar: DevDouble Close loop acceleration
ServoModeScalar: DevLong 0 -> servo off (open-loop), 1 -> servo on (close-loop)
MotorReferencedScalar: DevLong Indicates if motor is referenced. If not referenced (0) movement can not be performed.
HwLimitMaxScalar: DevDouble Maximum position value set in the hardware.
HwLimitMinScalar: DevDouble Minimum position value set in the hardware.
ConversionScalar: DevLong pos = steps/conversion + unitcalibration
UnitCalibrationScalar: DevDouble Offset to be added to the hardware position and software limits

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
CalibrateInput: DevDouble
Output: DevVoid
Software calibration (using UnitCalibration)
StopMoveInput: DevVoid
Output: DevVoid
—
ReadClearErrorInput: DevVoid
Output: DevLong
Error code
Read error and clear error status.
ReferenceMotorInput: DevVoid
Output: DevVoid
Performs a fast reference move to reference switch. If successful, absolute motion will afterwards be possible in closed-loop operation.
StartStepAndMeasurementInput: DevDouble
Amplitude
Output: DevVoid
Starts performing a step and recording the step response for the given axis. A ``step`` consists of a relative move of the specified amplitude which is performed relative to the current position. The axis must not be referenced before a measurement is performed.

Pipes:

Properties:

Name Description
CtrlDeviceDevString Name of the device of the class PiezoPiC867Ctrl connecting to the controller
AxisNbDevLong Axis number: 1 or 2

13 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 May 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



31 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Jun 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:22 May 2021, 3:59 a.m.