Average: 0
Rating Count: 0

Development status: New development
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/2D/Mar345Control
Contact:



Class Description


Families: Acquisition

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: Ethernet

Class interface


Attributes:

Name Description
FileStartNumberScalar: DevLong Image sequence number to be appended to the image prefix, 0 - 999. Will be incremented after each scan.
ScanModeScalar: DevLong Scan mode: 0 = 2300 pixels, 345 mm diameters, 0.15 mm pixelsize 1 = 2000 pixels, 300 mm diameters, 0.15 mm pixelsize 2 = 1600 pixels, 240 mm diameters, 0.15 mm pixelsize 3 = 1200 pixels, 180 mm diameters, 0.15 mm pixelsize 4 = 3450 pixels, 345 mm diameters, 0.10 mm pixelsize 5 = 3000 pixels, 300 mm diameters, 0.10 mm pixelsize 6 = 2400 pixels, 240 mm diameters, 0.10 mm pixelsize 7 = 1800 pixels, 180 mm diameters, 0.10 mm pixelsize
FilePrefixScalar: DevString The prefix of the filename, a file sequence number (according to FileStartNumber) and an extension (according to ScanMode) will be added by mar345 / scan345.
FileDirScalar: DevString The directory on the MarPC where scan images are stored. Please: - give an absolute path - check that the directory exists and the user running mar345 /scan345 has write permissions Existing files with the same prefix / number as given with FilePrefix / FileStartNumber will be overwritten.

Commands:

Name Description
ScanInput: DevVoid
Output: DevVoid
Start a scan and save image (see FileDir, FilePrefix, FileStartNumber)
EraseInput: DevVoid
Output: DevVoid
Erase image plate
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.

Pipes:

Properties:

Name Description
PortNumberDevUShort Port number of mar345/scan345 server on Mar PC
HostNameDevString host name / ip address of mar345 PC


Please log in to comment.

8 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



1 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Apr 2021, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:10 Apr 2021, 5:07 a.m.