Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MeasureInstruments/QudisController
Contact:



Class Description


Controller class for quDIS interferometer

Families: MeasureInstruments

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: https://www.qutools.com/

Product:

Bus: Not Applicable

Class interface


Attributes:

Name Description
FileStartNumScalar: DevULong64
FilePostfixScalar: DevString
FilePrefixScalar: DevString
FileDirScalar: DevString
EventsEnabledScalar: DevBoolean If true, asynchronous events are enabled. If false, not.
StreamingEnabledScalar: DevBoolean If true, streaming is enabled globally. If false, not.
PositionAverageTimeScalar: DevLong Average time that is applied to all relative and absolute positions. The parameter is logarithmic; the actual average time is calculated as follows: time = 40us * (2 ^ parameterValue). Range = 0 - 16 Affects all axes, the index field must be 0.
WaveLengthControlStateScalar: DevLong The state of the wavelength control: 0 : wavelength control ok 1 : wavelength control failure 2 : wavelength control initializing

Commands:

Name Description
GetAxisConfigInput: DevVarLongArray
0: axis number 1: abs/rel
Output: DevLong
0 = disabled, 2 = enabled
Read axis streaming config; internal use only, do not call directly.
SetAxisConfigInput: DevVarLongArray
0: axis number 1: abs/rel, abs = true, rel = false 2: enabled /disabled, enabled = true, disabled = false
Output: DevVoid
Configure axis for streaming; internal use only, do not call directly.
StopAcquisitionInput: DevVoid
Output: DevVoid
StartAcquisitionInput: DevVoid
Output: DevVoid
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.

Pipes:

Properties:

Name Description
ConnectTypeDevString How the device is connected: either `net` or `usb`.
DeviceNumberDevLong Number of the device (0 if only one device is connected)


Please log in to comment.

1 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



3 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Mar 2021, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:13 Mar 2021, 4:45 a.m.