This is historical information of device classes implemented in Magnet622 device server.
Use this link to find the valid information.
Development status:
Released,
Release: Release_1_2
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MagneticDevices/Magnet622
Contact:
Class Description
Tango device server for Cryogenic Ltd 6/2/2 magnet used at DESY, PETRA3, Beamline P01
Families: MagneticDevices
Key words:
Platform: Unix Like
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: Cryogenic Ltd
Bus: Ethernet
Class interface
Attributes:
| Name | Description |
|---|---|
| PhiTargetScalar: DevDouble | Get/set the target phi angle of the magnetic field (B), used in Spherical mode |
| ThetaTargetScalar: DevDouble | Get/set the target theta angle of the magnetic field (B), used in Spherical mode. (Commands VM_setTargetTheta / VM_getTargetTheta) |
| TemperatureTargetScalar: DevDouble | write / read the target needle valve cell temperature |
| Output1TargetTemperatureScalar: DevDouble | read / write the target temperature for output 1 |
| Output2TargetTemperatureScalar: DevDouble | read / write the target temperature for output 2 |
| Output3TargetTemperatureScalar: DevDouble | read / write the target temperature for output 3 |
| Output4TargetTemperatureScalar: DevDouble | read / write the target temperature for output 4 |
| SensorAScalar: DevDouble | read / write the value for sensor A |
| SensorBScalar: DevDouble | read / write the value for sensor B |
| SensorCScalar: DevDouble | read / write the value for sensor C |
| SensorDScalar: DevDouble | read / write the value for sensor D |
| CoordinateSystemScalar: DevBoolean | write / read the coordinate to either Cartesian (0) or Spherical (1) |
| TimeToTargetScalar: DevDouble | Get the time to target in units of seconds |
| PathCalculationTypeScalar: DevLong | write the Path Calculation Type. (0) Calculate by time, (1) Calculate by Ramp rate |
| PersistentModeScalar: DevBoolean | write / read the magnet persistent mode (true = on, false = off) |
| RotationDirectionScalar: DevLong | write / read the rotation direction if coordinate system is in Spherical mode 0 = anticlockwise, 1= clockwise |
| RotationAxisTypeScalar: DevLong | write / read the rotation axis type. If Z-axis (2) then the rotation will be about Z. if AxB (3) then it would rotate about the axis that is perpendicular to the initial and final vector. |
| MagnetReadyScalar: DevBoolean | read the ready status of the Vector Magnet(true = ready, false = not ready) If it is not ready then do not perform any path calculation or ramp. |
| RampTimeScalar: DevDouble | write / read the ramp time needed if Path calculation type (PathCalculationType) is set to calculate by time. |
| ThetaScalar: DevDouble | read the theta angle of the magnetic field (B), used in Spherical mode. |
| XFieldAmpsScalar: DevDouble | read the value of the X field in Amps |
| XFieldTeslaScalar: DevDouble | read the value of the X field in Tesla |
| TargetXFieldTeslaScalar: DevDouble | write / read the value of the Target X field in Tesla |
| XFieldRampRateScalar: DevDouble | write / read the X field Ramp rate, in units of A/s |
| YFieldAmpsScalar: DevDouble | read the value of the Y field in Amps |
| YFieldTeslaScalar: DevDouble | read the value of the Y field in Tesla |
| TargetYFieldTeslaScalar: DevDouble | write / read the value of the Target Y field in Tesla |
| YFieldRampRateScalar: DevDouble | write / read the Y field Ramp rate, in units of A/s |
| ZFieldAmpsScalar: DevDouble | read the value of the Z field in Amps |
| ZFieldTeslaScalar: DevDouble | read the value of the Z field in Tesla |
| ZFieldRampRateScalar: DevDouble | write / read the Z field Ramp rate, in units of A/s |
| TargetZFieldTeslaScalar: DevDouble | write / read the value of the Target Z field in Tesla |
| MotorAngleScalar: DevDouble | write / read the angle of the rotation motor |
| MotorHeightScalar: DevDouble | write / read the height of the vertical motor |
| MotionStatusScalar: DevLong | read the motion status of motors. 0 = No motion 1 = Vertical motion 2 = Rotation motion |
| HeightAtTargetScalar: DevBoolean | check whether height is at target position true = yes false = no |
| RotationAtTargetScalar: DevBoolean | check whether rotation is at target position true = yes false = no |
| TemperatureScalar: DevDouble | read the temperature of the needle valve cell |
| PressureScalar: DevDouble | read the the pressure |
| DumpPressureScalar: DevDouble | read the dump pressure |
| OutputPowerScalar: DevDouble | read the output power |
| MagneticFieldScalar: DevDouble | read the magnitude of the magnetic field, used in Spherical mode |
| MagneticFieldTargetScalar: DevDouble | write / read the magnitude of the target magnetic field, used in Spherical mode |
| PhiAngleScalar: DevDouble | Get the phi angle of the magnetic field (B), used in Spherical mode |
| UserRotationAngleScalar: DevDouble | write / read the user rotation angle |
| ControllerStatusScalar: DevString | Display the current status message in the Status field at the bottom of the Temperature Control window on the Windows PC |
| UserRotationAxisSpectrum: DevDouble | write / read the user rotation axis vector x,y,z |
| TemperaturesSpectrum: DevDouble | Returns a list of temperature sensor values in the order shown in the Temperature Monitor. |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| CalculatePathInput: DevVoid Output: DevVoid |
Calculates the path to ramp to target |
| AbortRampInput: DevVoid Output: DevVoid |
Aborts ramp or path calculation |
| SetPersistentInput: DevVoid Output: DevVoid |
Set the magnet into persistent mode |
| StartRampInput: DevVoid Output: DevVoid |
Ramp the Magnet to target |
| StopMotorsInput: DevVoid Output: DevVoid |
Stop all motors from moving |
Pipes:
Properties:
| Name | Description |
|---|---|
| HostNameDevString | Name / IP address of controller PC |
| PortNumberDevString | Port number of service on controller PC |
Updated:
The device class has been updated.
You are looking at this version now.
27 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
19 Dec 2020, DS Admin
Created:
The device class has been added to catalogue.