Development status:
Released,
Release: Release_1_10
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/PowerSupply/HVisegEHS80
Contact:
Class Description
Class for HV Power Supply EHS 80 vvx from iseg
Families: PowerSupply
Key words:
Platform: All Platforms
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: iseg
Product:
EHS80
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| ChannelStatusScalar: DevDouble | Off (0), On (1), resetEmergencyOff (2), setEmergencyOff (3), clearEvents (10)\n\nRead: An enumerated value which shows the current state of\n the output channel.\n Write: Change the state of the channel.\n If the channel is On, and the write value is Off, then the channel\n will switch Off.\n If the channel is Off, and the write value is On, and if no other\n signals (mainInhibit, outputInhibit, outputEmergencyOff or outputFailureMaxCurrent)\n are active, then the channel will switch on.\n \n If the write value is resetEmergencyOff, then the channel will \n leave the state EmergencyOff. A write of clearEvents is necessary\n before the voltage can ramp up again.\n If the write value is setEmergencyOff, then the channel will have \n the state EmergencyOff, which means that the High Voltage will \n switch off without a ramp and reset of the outputVoltage to null volt.\n \n If the write value is clearEvents, then all failure messages \n of the outputStatus will be reset (all channel events, all module events\n and the state emergencyOff). |
| MeasTerminalVoltageScalar: DevDouble | The measured voltage at the output terminals. |
| MeasSenseVoltageScalar: DevDouble | The measured voltage at the sense input lines. |
| SetCurrentScalar: DevDouble | The current limit of the channel. |
| MeasCurrentScalar: DevDouble | The measured output current. |
| RampSpeedScalar: DevDouble | Voltage Rise Slew Rate [V/s].\n\nThe slew rate of the output voltage if it increases\n\n(after switch on or if the Voltage has been changed. |
| ChannelStatusStrScalar: DevString | — |
| SetVoltageScalar: DevDouble | The nominal output voltage of the channel. |
| CrateSlotScalar: DevLong | Crate Slot (from 1 to 5) |
| ChannelNumberScalar: DevLong | Channel Number (from 1 to 16) |
| RampSpeedDownScalar: DevDouble | Voltage Fall Slew Rate [V/s].\n |
| ResistanceScalar: DevDouble | MeasSenseVoltage/MeasCurrent |
| OutputStatusScalar: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
| SafetyLoopResetInput: DevVoid Output: DevVoid |
Reset module after Safetyloop error. |
Pipes:
Properties:
| Name | Description |
|---|---|
| HVisegMPODCtrlDeviceDevString | Name of the HVisegMPODCtrl device making the Ethernet connection. |
| SimulationModeDevULong | 0 -> real mode, 1 -> simulation mode |
| ChannelNbDevLong | Channel Number (from 1 to 16) |
| CrateSlotDevLong | Crate Slot (from 1 to 5) |
Please log in to comment.
Generated
Updated:
The device class has been updated.
You can see previous version here .
21 Jul 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
7 Jul 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.