Development status:
New development
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/2D/Simplon
Contact:
Class Description
Maps the Dectris Eigers Simplon API modules to tango devices. All supported parameters are dynamically added as commands or attributes. Single parameters can be ignored or set to expert view level through device properties.
Families: Acquisition
Key words:
Platform: All Platforms
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: Dectris
Product:
Simplon API
Bus: TCP/UDP
Class interface
Attributes:
Commands:
Name | Description |
---|---|
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
Pipes:
Properties:
Name | Description |
---|---|
OperatorViewDevString | Comma separated list of attributes (for example ``PixelMask``) or commands which should be set to operator view level. Supports one asterisk as wildcard per identifier. If this property is set, all attributes and commands not listed here will be set to expert view level. |
ExpertViewDevString | Comma separated list of attributes (for example ``PixelMask``) or commands which should be set to expert view level. Supports one asterisk as wildcard per identifier. |
IgnoreDevString | Comma separated list of attributes (for example ``PixelMask``) or commands which should not be exported. Supports one asterisk as wildcard per identifier. |
VersionDevString | Simplon API version |
ModuleDevString | Simplon module (``detector``, ``filewriter``, ``monitor``, ``stream``, ``system``) to map. |
HostDevString | Hostname or IP address of the DCU where Simplon API is running on. |
Please log in to comment.
Updated:
The device class has been updated.
You can see previous version here .
16 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
9 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
2 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
26 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
19 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
12 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
5 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
28 Nov 2020, DS Admin
Created:
The device class has been added to catalogue.