Development status:
New development
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Calculation/MeasuredFillingPattern
Contact:
Class Description
Device to ...
Families: Calculation
Key words:
Platform: All Platforms
Language: Python
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| FilledBunchesScalar: DevShort | — |
| OffsetHScalar: DevDouble | Oscilloscope Horizontal Offset |
| OffsetH_expertScalar: DevDouble | Oscilloscope Horizontal Offset |
| ScaleHScalar: DevDouble | Oscilloscope Horizontal Scale |
| ScaleH_expertScalar: DevDouble | Oscilloscope Horizontal Scale |
| SpuriousBunchesScalar: DevShort | — |
| StartingPointScalar: DevShort | — |
| StartingPoint_expertScalar: DevShort | — |
| ThresholdScalar: DevDouble | — |
| Threshold_expertScalar: DevDouble | — |
| TimingTriggerScalar: DevShort | — |
| TimingTrigger_expertScalar: DevShort | — |
| emitCyclicBufferScalar: DevBoolean | This boolean attribute is to allow or not to emit the events on the cyclic Buffer. This is because it can cause delay dou to be too big buffer |
| nAcquisitionsScalar: DevUShort | Number of elements in the cyclic buffer from where the calculation takes the data. |
| nBunchesScalar: DevShort | — |
| resultingFrequencyScalar: DevDouble | Expert attribute to read the frequency with this device is pushing results in the output |
| CurrentSampleRateScalar: DevDouble | — |
| BunchIntensitySpectrum: DevDouble | — |
| CyclicBufferTraceSpectrum: DevString | Internal use attribute to have information about how the buffer changes |
| InputSignalSpectrum: DevDouble | — |
| cyclicBufferImage: DevDouble | Expert attribute to be able to check the cyclic buffer evolution |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| StartInput: DevVoid Output: DevVoid |
— |
| StopInput: DevVoid Output: DevVoid |
— |
| ExecInput: DevString statement to executed Output: DevString result |
— |
Pipes:
Properties:
| Name | Description |
|---|---|
| AutoStartDevBoolean | Configure if the device must start the calculation by default when it is launched |
| FCTAttributeDevString | Channel of the scope from where the readings are get |
| RfGeneratorAttrDevString | RfGenerator Attr name from where the frequency is read from time to time |
| RfGeneratorDevDevString | RfGenerator Device name from where the frequency is read from time to time |
| dcctAttrDevString | DCCT Attr name from where the sr current is read from time to time |
| dcctDevDevString | DCCT Device name from where the sr current is read from time to time |
| erDevDevString | Event Receiver Device name |
| scoDevDevString | Scope Device name where one channel has the FCT signal |
Class Description
Device to ...
Families: Calculation
Key words:
Platform: All Platforms
Language: Python
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| ThresholdScalar: DevUShort | — |
| Threshold_expertScalar: DevUShort | — |
| resultingFrequencyScalar: DevDouble | Expert attribute to read the frequency with this device is pushing results in the output |
| nBunchesScalar: DevShort | — |
| SpuriousBunchesScalar: DevShort | — |
| FilledBunchesScalar: DevShort | — |
| nAcquisitionsScalar: DevUShort | Number of elements in the cyclic buffer from where the calculation takes the data. |
| BunchIntensitySpectrum: DevDouble | — |
| InputSignalSpectrum: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| StartInput: DevVoid Output: DevVoid |
— |
| StopInput: DevVoid Output: DevVoid |
— |
| ExecInput: DevString statement to executed Output: DevString result |
— |
Pipes:
Properties:
| Name | Description |
|---|---|
| PhCtDevDevString | Photon Counter device name |
| AutoStartDevBoolean | Configure if the device must start the calculation by default when it is launched |
| PhCtAttrDevString | Photon Counter histogram property name |
| dcctAttrDevString | DCCT Attr name from where the sr current is read from time to time |
| dcctDevDevString | DCCT Device name from where the sr current is read from time to time |
Please log in to comment.
Updated:
A device class has been added.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.