MeasuredFillingPattern - - TANGO Controls

This is historical information of device classes implemented in MeasuredFillingPattern device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


Device to ...

Families: Calculation

Key words:

Platform: All Platforms

Language: Python

License:

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
FilledBunchesScalar: DevShort —
OffsetHScalar: DevDouble Oscilloscope Horizontal Offset
OffsetH_expertScalar: DevDouble Oscilloscope Horizontal Offset
ScaleHScalar: DevDouble Oscilloscope Horizontal Scale
ScaleH_expertScalar: DevDouble Oscilloscope Horizontal Scale
SpuriousBunchesScalar: DevShort —
StartingPointScalar: DevShort —
StartingPoint_expertScalar: DevShort —
ThresholdScalar: DevDouble —
Threshold_expertScalar: DevDouble —
TimingTriggerScalar: DevShort —
TimingTrigger_expertScalar: DevShort —
emitCyclicBufferScalar: DevBoolean This boolean attribute is to allow or not to emit the events on the cyclic Buffer. This is because it can cause delay dou to be too big buffer
nAcquisitionsScalar: DevUShort Number of elements in the cyclic buffer from where the calculation takes the data.
nBunchesScalar: DevShort —
resultingFrequencyScalar: DevDouble Expert attribute to read the frequency with this device is pushing results in the output
CurrentSampleRateScalar: DevDouble —
BunchIntensitySpectrum: DevDouble —
CyclicBufferTraceSpectrum: DevString Internal use attribute to have information about how the buffer changes
InputSignalSpectrum: DevDouble —
cyclicBufferImage: DevDouble Expert attribute to be able to check the cyclic buffer evolution

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartInput: DevVoid
Output: DevVoid
—
StopInput: DevVoid
Output: DevVoid
—
ExecInput: DevString
statement to executed
Output: DevString
result
—

Pipes:

Properties:

Name Description
AutoStartDevBoolean Configure if the device must start the calculation by default when it is launched
FCTAttributeDevString Channel of the scope from where the readings are get
RfGeneratorAttrDevString RfGenerator Attr name from where the frequency is read from time to time
RfGeneratorDevDevString RfGenerator Device name from where the frequency is read from time to time
dcctAttrDevString DCCT Attr name from where the sr current is read from time to time
dcctDevDevString DCCT Device name from where the sr current is read from time to time
erDevDevString Event Receiver Device name
scoDevDevString Scope Device name where one channel has the FCT signal

23 Feb 2017, Piotr Goryl
Updated:
A device class has been added.
You are looking at this version now.



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



3 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 9:42 a.m.