Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Communication/TangoToTine
Contact:



Class Description


The Tango to Tine gateway is implemented as a Tine server which maps Tango devices to Tine devices. To configure and to administer this Tine server in a Tango system, the Tango to Tine gateway wrapper can be used.

The Tine server will run as a thread of the Tango gateway wrapper server. Configuring the Tine server is possible by a set of Tango properties. This way the Tango to Tine gateway can be started and stopped via Astor and can be reconfigured with the init command. <p > Only the two attributes state and status are available for the Tango to Tine gateway wrapper. The state is ON when the Tine server is still answering on the network. In case of a hang-up, the state will be UNKNOWN. </p><p > The property DeviceList is used to configure the list of devices which should be mapped from Tango to Tine. Device names can contain the wilcard character *. The device names will be expanded during the initialization. </p><p > More details on the Tango to Tine gateway (as Tine server) can be found in the documentation of the Tine module. More information on meaning of the configuration properties is available in the <a href="http://adweb.desy.de/mcs/tine/index.html"> Tine documentation</a>. </p>

System Message: WARNING/2 (<string>, line 5); backlink

Inline emphasis start-string without end-string.

Families: Communication

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.

Pipes:

Properties:

Name Description
DeviceListArray of DevString List of Tango devices to be mapped as Tine devices. The character * can be used as wildcard for specifying device names.
TineContextDevString The Tine context to be used to register the Tine server.
TinePortOffsetDevLong The port offset for the Tine server.
TineSubSystemDevString The Tine sub system to be used for the Tine server.
TineLogPathDevString The path where the Tine log file will be written.
TineEqmNameDevString The name to be used to register the Tine equpment module. This name will be shown in Tine as the name of the Tine server.


Please log in to comment.

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:3 Jan 2017, 1:50 p.m.