Zebra - - TANGO Controls

This is historical information of device classes implemented in Zebra device server.

Use this link to find the valid information.

Development status: Released, Release: Release_1_2
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/OtherInstruments/Zebra
Contact:



Class Description


Class for controlling PS CCD Camera

Families: Instrumentation

Key words:

Platform: Unix Like

Language: Python

License:

Contact:

Hardware


Manufacturer: DLS controls group

Product:

Zebra

Bus: Socket

Class interface


Attributes:

Name Description
ArmScalar: DevLong —
TriggerIntervalScalar: DevDouble Time between consecutive triggers
NbTriggersScalar: DevLong —
TriggerPulseTimeScalar: DevDouble Time of a trigger pulse
TriggerPosWidthScalar: DevDouble Gate width, if negative it will be taken in decreasing pos
TriggerPosStartScalar: DevDouble Encoder position for starting the gate
EncoderSpectrumSpectrum: DevDouble —
Encoder2SpectrumSpectrum: DevDouble —
Encoder3SpectrumSpectrum: DevDouble —
Encoder4SpectrumSpectrum: DevDouble —
TimeStampSpectrum: DevDouble —

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
ResetInput: DevVoid
Output: DevVoid
—
CalibrateInput: DevDouble
Position to calibrate
Output: DevVoid
—
CalibrateEnc1Input: DevDouble
Position to calibrate
Output: DevVoid
—
CalibrateEnc2Input: DevDouble
Position to calibrate
Output: DevVoid
—
CalibrateEnc3Input: DevDouble
Position to calibrate
Output: DevVoid
—
CalibrateEnc4Input: DevDouble
Position to calibrate
Output: DevVoid
—

Pipes:

Properties:

Name Description
IPAdressDevString IP Adress or Serial Device in case of direct USB connection
PortNbDevLong Port Number. Set to -1 in case of direct USB connection (serial device)
TTLOutputMaskDevLong Selects the TTL outputs where the trigger will be generated (ex. 1 -> only ttl 1, 3 -> ttl 1 and 3, 8 -> only ttl 4)
EncoderMaskDevLong Selects the encoders to be readout (ex. 1 -> only enc 1, 3 -> enc 1 and 3, 8 -> only enc 4)
GateTriggByPosDevLong If 1 the gate for starting the trigger pulses is triggered by a set enconder position. If 0 the gate is triggered by time
EncoderPosTriggerDevLong Number of the encoder used for triggering in position
PosConversionFactor1DevDouble Factor for converting encoder unit to physical units: enc_pos = phy_pos * factor. Used for calibrate encoder 1 readout
PosOffset1DevDouble Offset in enc position: enc_pos = offset + phy_pos * factor. Used for calibrate encoder 1 readout
PosConversionFactor2DevDouble Factor for converting encoder unit to physical units: enc_pos = phy_pos * factor. Used for calibrate encoder 2 readout
PosOffset2DevDouble Offset in enc position: enc_pos = offset + phy_pos * factor. Used for calibrate encoder 2 readout
PosConversionFactor3DevDouble Factor for converting encoder unit to physical units: enc_pos = phy_pos * factor. Used for calibrate encoder 3 readout
PosOffset3DevDouble Offset in enc position: enc_pos = offset + phy_pos * factor. Used for calibrate encoder 3 readout
PosConversionFactor4DevDouble Factor for converting encoder unit to physical units: enc_pos = phy_pos * factor. Used for calibrate encoder 4 readout
PosOffset4DevDouble Offset in enc position: enc_pos = offset + phy_pos * factor. Used for calibrate encoder 4 readout

13 Jun 2020, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:13 Jun 2020, 4:14 a.m.