.

Average: 0
Rating Count: 0

Development status: Released, Release: Release_1_2
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Vacuum/PfeifferGauge
Contact:



Class Description


Class for controlling the vacuum pressure measurement and control devices from Pfeiffer.

Families: Vacuum

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: Pfeiffer

Product:

TPG262 and TPG256A

Bus: Data Socket

Class interface


Attributes:

Name Description
PressureSensor1Scalar: DevDouble
PressureSensor2Scalar: DevDouble
PressureUnitsScalar: DevString
SetPoint1Scalar: DevString Status (0 -> off, 1->on), min value, max value
SetPoint2Scalar: DevString Status (0 -> off, 1->on), min value, max value
SetPoint3Scalar: DevString Status (0 -> off, 1->on), min value, max value
SetPoint4Scalar: DevString Status (0 -> off, 1->on), min value, max value
SensorStatus1Scalar: DevString Sensor Status: Ok = Messdaten okay Ur = Messbereichsunterschreitung (Underrange) Or = Messbereichsüberschreitung (Overrange) SenErr = Messstellenfehler (Sensor-Error) Off = Messstelle ausgeschaltet None = keine Messröhre IdErr = Identifikationsfehler Ukn = Unknown, still not tried to readout
SensorStatus2Scalar: DevString Sensor Status: Ok = Messdaten okay Ur = Messbereichsunterschreitung (Underrange) Or = Messbereichsüberschreitung (Overrange) SenErr = Messstellenfehler (Sensor-Error) Off = Messstelle ausgeschaltet None = keine Messröhre IdErr = Identifikationsfehler Ukn = Unknown, still not tried to readout

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
WriteReadRawInput: DevString
Message to send
Output: DevString
Raw answer
Sends a command to the device and returns the answer.

Pipes:

Properties:

Name Description
PortNbDevLong Port number
SimulationModeDevLong 0-> no simulation
HostNameDevString Name of the terminal server connecting to the device
TPGTypeDevLong Type of TPG device device: 262, 256


Please log in to comment.

1 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:2 Jan 2017, 3 p.m.