Class Description


Controll of the ADQ214 digitizer from SP Devices

Families: OtherInstruments

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: SP Devices

Product:

ADQ214

Bus: USB

Class interface


Attributes:

Name Description
AcqModeScalar: DevLong Acquisition mode: 0 -> multirecord, 1 -> wfa, 2 -> atd
TemperatureScalar: DevDouble —
NbRecordsScalar: DevLong Number of records to acquire.
NbSamplesPerRecordScalar: DevLong Number os samples per record to acquire
RecordsCollectedScalar: DevLong Records collected in current/last acquisition
ClockSourceScalar: DevLong 0 -> int_intref 1 -> int_extref 2 -> ext
TriggerModeScalar: DevLong 1 -> software 2 -> external 3 -> level 4 -> internal
InputRangeChAScalar: DevDouble —
InputRangeChBScalar: DevDouble —
LvlTrigChannelScalar: DevLong A mask that tells the ADQ which channels that are active • channels = 0 => None • channels = 1 => Channel A • channels = 2 => Channel B • channels = 4 => Channel C • channels = 8 => Channel D To trig on multiple channels add the channel code for each individual channel. Examples: • channels = 10 => Any of Channel B and D • channels = 15 => Any Channel Values given for any non-existing channel is simply ignored
LvlTrigEdgeScalar: DevLong Trigger edge
LvlTrigLevelScalar: DevLong Trigger level in codes
LvlTrigResetValueScalar: DevLong64 The offset from the trigger level for which the level trigger shall arm the trigger for detecting rising or falling edges. Read the last set value.
ExtTrigEdgeScalar: DevLong Specifies which edge to use: 0: Falling edge 1: Rising edge 2: Both edges (ADQ12 / ADQ14 only)
MultiRecordPreTriggerSamplesScalar: DevLong The number of pre-trigger samples. Must be less than the MultiRecord record size. Granularity ADQ214: 2 samples.
WFANbWaveformsScalar: DevLong The number of waveforms to average
WFANbSamplesScalar: DevLong The number of samples per waveform
WFAPreTriggerSamplesScalar: DevLong The number of pretrigger samples for each waveform
WFANbTriggerDelaySamplesScalar: DevLong The number of samples to hold off after the trigger event
WFAFlagsScalar: DevLong A bit mask that specifies different behaviours
ATDRecordLengthScalar: DevLong Length of record in samples. Multiple of 72 required
ATDNbAccumulationsScalar: DevLong Number of accumulations to perform. [1, 65536] supported with safe scaling
ATDNbRepitedAccuScalar: DevLong Number of times to repeat the accumulation, creating a new record. A value of 4294967295 (0xFFFFFFFF) indicates infinite repeats.
ATDPreTriggerSamplesScalar: DevLong The number of samples to collect from before the trigger point
ATDNbTriggerDelaySamplesScalar: DevLong The number of samples to wait before collecting data, after the trigger arrives
LiveModeScalar: DevBoolean If 1 acquisition will run continuously
FileDirScalar: DevString —
FilePrefixScalar: DevString —
DataStreamChASpectrum: DevDouble —
DataStreamChBSpectrum: DevDouble —

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartAcquisitionInput: DevVoid
Output: DevVoid
Start acquisition in the mode selected by AcqMode
StopAcquisitionInput: DevVoid
Output: DevVoid
—

Pipes:

Properties:

Name Description
SPADQIdxDevLong Index of the digitizer

3 Sep 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 Jul 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Jul 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Jul 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 Jul 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



2 Jul 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Jun 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Jun 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Jun 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Jun 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



21 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



14 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



7 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



2 Apr 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



19 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



12 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Feb 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



19 Feb 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



12 Feb 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Feb 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



29 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



15 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



8 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



1 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Dec 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Dec 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Dec 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Dec 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



2 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



21 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



14 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



7 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



31 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



3 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



19 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



12 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



29 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



15 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



1 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



3 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



2 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



19 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



12 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



21 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



14 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



7 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



31 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



3 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



19 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



12 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



29 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



15 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



8 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



1 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



2 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



21 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



14 Mar 2020, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



7 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



29 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



15 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



8 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



1 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Jan 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Jan 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Jan 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Jan 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 Dec 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



21 Dec 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



14 Dec 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



7 Dec 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 Nov 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Nov 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Nov 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 Nov 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



2 Nov 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Oct 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



19 Oct 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



12 Oct 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Oct 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 Sep 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



21 Sep 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



14 Sep 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



7 Sep 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



31 Aug 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Aug 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Aug 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Aug 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



3 Aug 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Jul 2019, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:14 Mar 2020, 4:10 a.m.