Development status:
Released,
Release: Release_1_0
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/BeamlineComponents/AnalyzerCA
Contact:
Class Description
Tango for controlling an analyzer
Families: BeamlineComponents
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| PositionScalar: DevDouble | Analyzer energy |
| UnitLimitMinScalar: DevDouble | — |
| UnitLimitMaxScalar: DevDouble | — |
| PositionSimScalar: DevDouble | — |
| CrystalSpacingSiScalar: DevDouble | — |
| CrystalSpacingSiO2Scalar: DevDouble | — |
| AlphaSiScalar: DevDouble | — |
| AlphaSiO2Scalar: DevDouble | — |
| PosDetXScalar: DevDouble | — |
| PosDetYScalar: DevDouble | — |
| PosMan1XScalar: DevDouble | — |
| PosMan1YScalar: DevDouble | — |
| ResultSimSpectrum: DevString | Show the motor positions for the energy written in PositionSim |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| CalibrateInput: DevDouble Value to be calibrated to Output: DevVoid |
— |
| StopMoveInput: DevVoid Output: DevVoid |
Stop all motors |
Pipes:
Properties:
| Name | Description |
|---|---|
| CollimatorThetaDevString | Name of the tango device for the CollimatorTheta motor |
| AnalyzerThetaDevString | Name of the tango device for the AnalyzerTheta motor |
| MotX1DevString | Name of the tango device for the MotX1 motor |
| MotY1DevString | Name of the tango device for the MotY1 motor |
| MotX2DevString | Name of the tango device for the MotX2 motor |
| MotY2DevString | Name of the tango device for the MotY2 motor |
Please log in to comment.
Updated:
The device class has been updated.
You can see previous version here .
8 Dec 2018, DS Admin
Created:
The device class has been added to catalogue.